10.3.16.3
Degas / Degas break
The time between two degassing intervals is set under “degas break”.
If a metering request is submitted during this period, this is processed and the Degas
PLUS
break time is reset and restarted.
Default setting = 00:00
Setting range:
hours
00 bis 23
minutes
00 bis 59
total
00:01 bis 23:59 h
Fig. 76: Configuration Degas
PLUS
Degas break
10.4
Calibration
10.4.1 Overview
The procedure and display during the calibration process differ depending on whether or
not an oval gear meter (OGM) is connected.
Fig. 77: Calibration Overview
Calibration pump:
Chapter 10.4.2 ‘Calibration / Pump’ on page 100
.
Calibration pump with OGM:
Chapter 10.4.3 ‘Calibration pump with oval gear meter (OGM
.
Menu description
99
417101442 Rev. 12-02.2019