![Ecolab Elados EMP KKS E60 Operating Instructions Manual Download Page 246](http://html.mh-extra.com/html/ecolab/elados-emp-kks-e60/elados-emp-kks-e60_operating-instructions-manual_2354530246.webp)
11.2
Replacing the diaphragm and pump head
Fig. 87: Maintenance: Replacing the diaphragm and pump head
1
Pump head
2
Metering head screw
3
Ceramics piston
4
Diaphragm unit
5
Bellows
6
Intermediate plate
WARNING!
Before opening pump head:
empty connecting lines, rinse the pump head, the ceramics cylinder can be
destroyed when being set on edges!
1.
Loosen the metering head screws (pos. 2).
2.
Take off the pump head (pos. 1) absolute straightly.
3.
Take ceramics piston (pos. 3) sideways out of the coupling of the diaphragm unit
(pos. 4).
4.
Un screw diaphragma unit (pos. 4).
5.
Remove intermediate plate (pos. 6).
6.
Exchange bellows (pos. 5).
7.
Do not overdraw the diaphragm unit (pos. 4) when tightening, screw
gently
until
stop.
8.
The leakage connection of the intermediate plate (pos. 6) must be directed
downwards.
9.
Re-insert the piston (pos. 3).
10.
Attach cylinder carefully on the pump head.
11.
Hand-screw pump head screws.
12.
Screw-down cross-over pump head screws.
WARNING!
Check metering head bolt tightening torque after 24 hours.
Screw down the pump head absolute straight. Tighten the metering head
evenly diagonally.
*1 Correct tightening torque: 3 to 4 Nm.
Maintenance
110
417101442 Rev. 12-02.2019
Summary of Contents for Elados EMP KKS E60
Page 2: ......
Page 123: ...14 2 Abmessungen Abb 89 Abmessungen Technische Daten 121 417101442 Rev 12 02 2019 ...
Page 135: ......
Page 258: ...14 2 Dimensions Fig 90 Dimensions Technical Specifications 122 417101442 Rev 12 02 2019 ...
Page 393: ...14 2 Dimensions Fig 93 Dimensions Données techniques 123 417101442 Rev 12 02 2019 ...
Page 405: ......