WARNING!
The installation must only be performed by authorized personnel and the
general guidelines and local installation regulations must be observed!
– The metering pump should be fitted in an easy-to-access, frost-free
location.
The ambient temperature must not 40° C.
– The mounting position of the device must be horizontal.
– The pump must be securely screwed to the bracket or the container using
Chapter 14.2 ‘Dimensions’ on page 122
6.1
Mounting diagram
NOTICE!
The pump must be screwed firmly to the console or container using the holes
provided for this purpose (hole spacing
).
Fig. 7: Mounting diagram
1
pressure relief valve
2
metering valve / pressure control valve
3
suction pipe / bottom admission valve
The metering valve, pressure control valve and pressure relief valve can be
replaced by a multifunction valve (MFV) from our product range, which
combines all of these functionalities.
Mounting
31
417101442 Rev. 12-02.2019