Firmware V3.15
21.04.2021
63/401
Timing relay function for service counters (controller type UA 141)
Via a voltage pulse applied (e.g. by on-site pushbutton switch, min. 10 sec.) to the digital input 3 for the frame
heater (terminal D31/D32, (factory setting). causes the corresponding relay of the Case Controller to energize
and subsequently de-energize after completion of the set pane heater on time.
This function is available on the UA 141 supplementary to the fixed on time or enthalpy-controlled on time
functions. To ensure compatibility with earlier software versions, a fixed on time of 0% is set on the UA 141 at
first start, meaning that the pane heater is then controlled exclusively by the timing relay function. The function
of the digital input can be configured via the parameter „
Inv. D3
" (i.e. Inv. D2) in menu 6-2-4.
On time interval
The full time interval for the frame and pane heater is 10 minutes, meaning that the frame heater will be ON for
1 minute and OFF for 9 minutes when set to 10%.
Defrosting
The frame heater is off during defrosting. With the UA 131 the frame heater is always switched off during
defrosting. The frame heater is switched off according to the status of the first defrost zone. With other
controller types, not the UA 131, the frame heater is not switched off during defrosting.
The timing relay function can be activated via digital Input 1 (terminals D11 and D12). This requires
digital Input 3 to be set as PANE ACTU. for the switch on/off function to be available.
Summary of Contents for UA 400
Page 26: ...Firmware V3 15 21 04 2021 26 401 Solenoid valve Relay for Solenoid Valve 1...
Page 172: ...Firmware V3 15 21 04 2021 172 401 Service Mode 6 7 2 SERVICE MOD...
Page 244: ...Firmware V3 15 21 04 2021 244 401...
Page 361: ...Firmware V3 15 21 04 2021 361 401 FANS 2 Pos XXXXX Fan Delay Fan delay...
Page 372: ...Firmware V3 15 21 04 2021 372 401...