7.11 Terminal assignment of the analogue inputs for temperature sensors
Sensor 1
Sensor 2
Sensor 3
Sensor 4
Sensor 5
Sensor 6
Sensor 7
Sensor 8
Sensor 9
Sensor 10
Controller
type
Z11/Z12
Z21/Z22
Z31/Z32
Z41/Z42
Z51/Z52
Z61/Z62
Z71/Z72
Z81/Z82
Z91/Z92
Z01/Z02
Case controller
UA 111
R2.1
R4.1
R2.2
R4.2
R2.3
R4.3
R2.4
R4.4
–
–
UA 111 D
R2.1
R4.1
R2.2
R4.2
R2.3
R4.3
R2.4
R4.4
R2.5
R4.5
UA 121
R2.1
R4.1
R1.1
R4.2
R1.2
R2.3
R4.3
R1.3
R4.4
R1.4
UA 131 / UA
131 LS
R2.1
R4.1
R1.1
R4.2
R1.2
R2.3
R4.3
R1.3
R4.4
R1.4
UA 131 DD
R2.1
R4.1
R1.1
R4.2
R1.2
R2.3
R4.3
R1.3
R4.4
R1.4
UA 141
R2.1
R4.1
R2.2
R4.2
R2.3
R4.3
R2.4
R4.4
–
–
Warning about dangerous electrical voltage!
If mains power is connected to the analogue inputs,
this results in destruction of the controller!
Malfunction due to interference!
All supply lines from and to the case controller must be shielded
(cable type: LiYCY)! If sensor cables are exclusively laid within the refrigerated case to be monitored
and sources of interference (e.g. parallel power lines) are not anticipated, then it is possible to
dispense with shielding. As a general rule, care should be taken to ensure that signal cables and
cables carrying mains voltage are routed in separate cable channels The case controller analogue
inputs are
only
approved for the connection of temperature sensors as named in chapter
.
Summary of Contents for UA 400
Page 26: ...Firmware V3 15 21 04 2021 26 401 Solenoid valve Relay for Solenoid Valve 1...
Page 172: ...Firmware V3 15 21 04 2021 172 401 Service Mode 6 7 2 SERVICE MOD...
Page 244: ...Firmware V3 15 21 04 2021 244 401...
Page 361: ...Firmware V3 15 21 04 2021 361 401 FANS 2 Pos XXXXX Fan Delay Fan delay...
Page 372: ...Firmware V3 15 21 04 2021 372 401...