A.2
A.2
A.2
A.2 Technical
Technical
Technical
Technical data:
data:
data:
data: xLogic
xLogic
xLogic
xLogic (ELC
(ELC
(ELC
(ELC series)
series)
series)
series)
Note:
Note:
Note:
Note: The
The
The
The following
following
following
following function
function
function
function block
block
block
block cannot
cannot
cannot
cannot be
be
be
be used
used
used
used in
in
in
in ELC-6
ELC-6
ELC-6
ELC-6 series
series
series
series
Constant (Cursor key, Sms input/output,Sms message input/output)
Analog (Analog MUX, PI Controller,Analog Ramp,Analog Math,Analog Math error detection)
Miscellaneous(Message texts, Pwm,Modbus Read,Modbus Write)
Standard
Standard
Standard
Standard
CPU
CPU
CPU
CPU
Units
Units
Units
Units(ELC-6
(ELC-6
(ELC-6
(ELC-6 series)
series)
series)
series)
ELC-6AC-R
ELC-6AC-R
ELC-6AC-R
ELC-6AC-R
ELC-6DC-D-R
ELC-6DC-D-R
ELC-6DC-D-R
ELC-6DC-D-R
ELC-6DC-D-TN
ELC-6DC-D-TN
ELC-6DC-D-TN
ELC-6DC-D-TN
Inputs
4 digital
4 digital
4 digital
of which can be used in
analog mode
none
none
none
Input/supply voltage
110-240V AC
12-24V DC
12-24V DC
Permissible range
with signal “0”
with signal “1”
Input current
85 ... 265 V AC
100 ... 253 V DC
max. 40 V AC 0.03 mA
min. 79 V AC, 0.08 mA
10.8 V ... 28.8 V DC
max. 3 V DC,1mA
min. 8 V DC,1.5 mA
10.8 V ... 28.8 V DC
max. 3 V DC, 1mA
min. 8 V DC,1.5 mA
Outputs
2 relays
2 relays
2 transistors(PNP)
Continuous current
10 A with resistive
load;
2 A with inductive load
10 A with resistive load;
2 A with inductive load
0.3 A
Short-circuit protection
External fuse required
External fuse required
External fuse required
Switching frequency
2 Hz with resistive
load;
0.5 Hz with inductive
load
2 Hz with resistive load;
0.5 Hz with inductive load
10 Hz
Cycle time
< 0.1 ms/function
< 0.1 ms/function
< 0.1 ms/function
Integrated time switches/
power reserve
Yes / typ. 72 h
Yes / typ. 72 h
Yes / typ. 72 h
Connection cables
2 x 1.5 mm
²
or 1 x 2.5 mm
²
Ambient temperature
0 to + 55 ºC
Storage temperature
– 40 ºC to + 70 ºC
Degree of protection
IP20
Certification
CE
Mounting
On 35 mm standard mounting rail, 4 MW, or wall-mounting
Dimensions
W x H x D
(48*90*64
mm)
Programming cable
PC cable, (RS232 or
USB)
PC cable, (RS232 or USB)
PC cable, (RS232 or
USB)
xLogic <=> xLogic
communication (RS485)
No
No
No
xLogic <=> network
(Ethernet)
No
No
No
Third party device(HMI)
<=> xLogic
Yes (modbus)
Yes (modbus)
Yes (modbus)
Maximum program
memory
64 blocks
64 blocks
64 blocks
External memory module
No
No
No
Data logging
Yes(ELC-MEMORY)
Yes(ELC-MEMORY)
Yes(ELC-MEMORY)
Extensions
No
No
No
High speed input
No
No
No
RTC
Yes
Yes
Yes
HMI
No
No
No
Summary of Contents for xLogic
Page 1: ......
Page 2: ......
Page 102: ...100 100 100 100 B B B B Blocks Blocks Blocks Blocks...
Page 105: ...103 103 103 103 G G G G M M M M status status status status...
Page 106: ...104 104 104 104 H H H H AM AM AM AM value value value value...
Page 164: ...162 162 162 162 If the Memory Read block had been triggered the Q1 of ELC 12 CPU will be set 1...
Page 204: ...202 202 202 202 Step Step Step Step 6 6 6 6 Moving Moving Moving Moving...
Page 226: ...224 224 224 224...