214
ESI-32 Operation Manual
Troubleshooting
This section explains some of the problems you might possibly encoun-
ter while working with the ESI-32. Before assuming that your ESI-32 is
faulty, check the following list which details the corrective action you
can take yourself without having to call a service center. If you have any
doubts or questions, get in touch with your nearest E-mu dealer or call
the E-mu customer service department at (408) 438-1921, between the
hours of 8:30 am and 5:30 pm Monday through Friday.
The ESI-32 seems dead
If the ESI-32 seems dead, first disconnect any external SCSI devices and
try again.
Problem:
The unit is completely dead. No lights no sound.
Cause:
The power supply may be damaged.
Solution:
Consult your dealer or authorized E-mu service center.
Audio Problems
Problem:
The ESI-32 powers up normally, but does not make any
sound.
Cause:
Proper audio connections may not have been made.
Solution:
Try listening directly to the stereo output using head-
phones to verify that the ESI-32 is at fault. Check that
proper audio connections have been made.
Problem:
The ESI-32 powers up normally, but does not make any
sound.
Cause:
The front panel volume control may need recalibration.
Solution:
Recalibrate the volume control using the Recalibrate
function located under Special in the Master/Global
module.
Problem:
The ESI-32 powers up normally, but does not make any
sound.
Cause:
Proper MIDI connections may not have been made.
Solution:
Try using the trigger buttons to play the ESI. Check
MIDI activity LED. Verify that proper MIDI connections
have been made.
Problem:
The digital audio output level is too low when a single
channel is played.
Cause:
Because of the nature of sampling instruments, each
additional channel played adds +3 dB to the headroom
requirement. A single channel on the ESI-32 comes out
about -6 dB down.
Solution:
Make sure the Master Volume control is at maximum.
Set the headroom adjustment (Master/Global, Special, 3)
to 0 dB. All volume adjustments in the ESI-32 affect the
digital output level.
Summary of Contents for ESI-32
Page 4: ...iv ESI 32 Operation Manual ...
Page 10: ...2 ESI 32 Operation Manual ...
Page 26: ...18 ESI 32 Operation Manual ...
Page 28: ...20 ESI 32 Operation Manual ...
Page 36: ...28 ESI 32 Operation Manual ...
Page 64: ...56 ESI 32 Operation Manual ...
Page 100: ...92 ESI 32 Operation Manual ...
Page 102: ...94 ESI 32 Operation Manual ...
Page 114: ...106 ESI 32 Operation Manual ...
Page 166: ...158 ESI 32 Operation Manual ...
Page 188: ...180 ESI 32 Operation Manual ...
Page 206: ...198 ESI 32 Operation Manual ...
Page 208: ...200 ESI 32 Operation Manual ...