Digital Processing
119
Selected
Selected
Zero X Threshold
(Set at -30 dB)
Ignored
Ignored
-96dB
-30dB
Slope of
Wave
+
-
Slope of
Wave
+
-
-96dB
-30dB
Adjust the zero crossing threshold according to the type of wave you are processing. A setting of -96
dB is most sensitive and can be used for finding the start point of a sound. Settings closer to -30 dB
are less sensitive and suited for finding zero-crossings in complex waves.