27
L I N X W I T H A T R A F L E X I N S T A L L A T I O N
Pulley Mounting Plates and Outer Bearings Installation
Version 3
Linx with Atra Flex Installation for Model 424 Automotive Dynamometers
I
NSTALLING
THE
I
DLER
P
ULLEY
O
UTER
B
EARING
, B
EARING
M
OUNTING
P
LATE
, L
INX
D
ETECT
S
ENSOR
,
AND
L
OWER
P
ULLEY
M
OUNT
1
Secure the Linx detect sensor to the mounting plate using two #8-32 screws.
2
Loosely secure the Linx detect sensor and mounting plate assembly to the
mounting bracket using two #8-32 screws. Leave these screws loose to align the
sensor with the tab
3
Attach the Linx detect sensor cable to the sensor.
Figure 17: Install the Linx Detect Sensor and Mounting Plate to the Mounting Bracket
4
Secure the Linx detect sensor mounting bracket and the outer idler bearing to the
idler bearing mounting plate using four 9/16-12 x 2-inch bolts, four 9/16-inch flat
washers, and four 9/16-inch nuts. Slide this assembly onto the idler shaft.
Figure 18: Install the Sensor Mounting Bracket, Outer Idler Pulley Bearing, and Bearing Mounting Plate
Linx detect
sensor
mounting plate
mounting bracket
attach cable
idler bearing
plate
sensor mounting
bracket
outer idler
bearing