L I N X W I T H A T R A F L E X I N S T A L L A T I O N
Drive Pulley Installation
Linx with Atra Flex Installation for Model 424 Automotive Dynamometers
20
4
Slide the grooved pulley onto the outer shaft with the narrow end of the tapered
bore towards the bearing plate.
5
Slide the taper lock bushing onto the outer shaft and into the taper of the pulley.
6
Place the bushing into the grooved pulley.
Note:
Insert the bushing into the larger diameter end of the pulley tapered hole.
7
Loosely secure the bushing in the pulley using the three included bolts and lock
washers.
Figure 12: Install the Pulley and Bushing
grooved pulley
tapered
bushing
section view of bushing
and grooved pulley to
show correct alignment
with the tapered hole
taper lock bushing
pulley
outer shaft
pulley plate