Maintenance - 50h
4812162501_F.pdf
2018-04-25
3
6
4
5
2
Fig. Air cleaner
1. Clips
2. Cover
3. Main filter
4. Backup filter
5. Filter housing
6. Dust valve
1
Release the clips (1), pull off the cover (2), and pull out
the main filter (3).
Do not remove the backup filter (4).
Clean the air cleaner if necessary, see section Air
cleaner - Cleaning.
When replacing the main filter (3), insert a new filter
and refit the air cleaner in the reverse order.
Check the condition of the dust valve (6); replace if
necessary.
When refitting the cover, make sure that the dust valve
is positioned downwards.
Backup filter - Change
Fig. Air filter
1. Backup filter
1
Change the backup filter with a new filter after every
third replacement of the main filter.
To change the backup filter (1), pull the old filter out of
its holder, insert a new filter and reassemble the air
cleaner in the reverse order.
Clean the air cleaner if necessary, see section Air
cleaner - Cleaning.
78
Summary of Contents for CS1400
Page 2: ......
Page 10: ...e 4812162501_F pdf 2018 04 25...
Page 14: ...Introduction 4812162501_F pdf 2018 04 25 4...
Page 22: ...Special instructions 4812162501_F pdf 2018 04 25 12...
Page 30: ...Technical specifications 4812162501_F pdf 2018 04 25 20...
Page 48: ...Machine description 4812162501_F pdf 2018 04 25 38...
Page 70: ...Operating instructions Summary 4812162501_F pdf 2018 04 25 60...
Page 72: ...Preventive maintenance 4812162501_F pdf 2018 04 25 62...
Page 80: ...Maintenance Maintenance schedule 4812162501_F pdf 2018 04 25 Service Checklist 70...
Page 92: ...Maintenance 50h 4812162501_F pdf 2018 04 25 82...
Page 98: ...Maintenance measures 500 h 4812162501_F pdf 2018 04 25 88...
Page 106: ...Maintenance 1000h 4812162501_F pdf 2018 04 25 96...
Page 117: ......
Page 118: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden www dynapac com...