Maintenance - 1000h
ICA250i-IN2EN1.pdf
2012-12-19
Rear axle differential - Oil change
Fig. Differential - Draining
1. Level/Filler plug
2. Drain plugs
3. Breather
Never work under the roller when the engine is
running. Park on a level surface. Block the wheels
securely.
Never work under the roller when the engine is
running. Park on a level surface. Block the wheels
securely.
Before draining the oil, use the breather (3) to release
possible internal pressure.
Wipe clean and remove one of the two level/filler plugs
(1) and the drain plug (2) and drain the oil into a
suitable receptacle. The volume is approximately 15
liters (16 qts).
Save the oil and hand in to an
environment-friendly waste disposal station.
Save the oil and hand in to an
environment-friendly waste disposal station.
Clean and refit the drainage plug (2) and tighten with
torque (60Nm)
Fig. Differential - filling
1. Level/Filler plugs
Fill with fresh oil in the level/filler hole until the oil level
reaches the lower edge of the plug hole. Use
transmission oil, see lubricant specification.
Note that it takes a while for the oil to be distributed in
the axle. Do not fill the entire volume at once.
Refit the level/filler plug (1) and tighten with torque
(25Nm).
78
Summary of Contents for CA250 i
Page 2: ......
Page 18: ...Special instructions ICA250i IN2EN1 pdf 2012 12 19 10...
Page 36: ...Machine description ICA250i IN2EN1 pdf 2012 12 19 28...
Page 56: ...Operating instructions Summary ICA250i IN2EN1 pdf 2012 12 19 48...
Page 58: ...Preventive maintenance ICA250i IN2EN1 pdf 2012 12 19 50...
Page 80: ...Maintenance 250h ICA250i IN2EN1 pdf 2012 12 19 72...
Page 92: ......
Page 93: ......