Maintenance - 250h
ICA250i-IN2EN1.pdf
2012-12-19
Drum - Checking the oil level
Fig. Roller, right-hand side
1. Filler plug
2. Number plate
3. Sight glass
1
2
3
Place the roller on a level surface so that the filler plug
(1) and the drum's number plate (2) are visible on the
right side of the drum.
The oil level should now reach the sight glass (3).
If necessary, remove the filler plug (1) and fill to
halfway up the sight glass.
Clean any metal residue from the magnetic filler plug
(1) before reinstalling it.
See the lubrication specification for the correct oil
grade.
Do not overfill with oil - risk for overheating.
Do not overfill with oil - risk for overheating.
Radiator - Check/Cleaning
Fig. Engine compartment
1. Water cooler
2. Hydraulic fluid cooler
3. Charge air cooler
1
3
2
Check that air can pass unobstructed through the
radiators (1) and (2).
Clean a dirty radiator using compressed air or a
high-pressure water jet.
Blow air or direct water through the cooler in the
opposite direction to that of the cooling air.
Be careful when using a high-pressure washer -
do not place the nozzle too close to the radiator.
Be careful when using a high-pressure washer -
do not place the nozzle too close to the radiator.
Wear protective goggles when working with
compressed air or high-pressure water jets.
Wear protective goggles when working with
compressed air or high-pressure water jets.
69
Summary of Contents for CA250 i
Page 2: ......
Page 18: ...Special instructions ICA250i IN2EN1 pdf 2012 12 19 10...
Page 36: ...Machine description ICA250i IN2EN1 pdf 2012 12 19 28...
Page 56: ...Operating instructions Summary ICA250i IN2EN1 pdf 2012 12 19 48...
Page 58: ...Preventive maintenance ICA250i IN2EN1 pdf 2012 12 19 50...
Page 80: ...Maintenance 250h ICA250i IN2EN1 pdf 2012 12 19 72...
Page 92: ......
Page 93: ......