SmartVue Operator’s Manual
10-0004-R13
13
To configure a Multipurpose I/O channel
1.
Press
MENU > Configure I/O > Multipurpose I/O.
2.
Press the button for the channel (DIO/VIN 1 to 6) that you wish to configure.
3.
Choose the desired I/O type:
Digital Input, Digital Output or Voltage Input.
4.
Configure the I/O channel:
Digital Input/Output
Label
The identifying label that will appear on the meter screen.
Low State
The characters that will be displayed on the meter screen for a
low digital input signal.
High State
Digital Input: The characters that will be displayed on the
meter screen for a high digital input signal.
HiZ State
Digital Output: The characters that will be displayed on the
meter screen when the output is in a high impedance state.
Pull-up
Turns the pull-up resistor on or off for the given digital input or
output.
Voltage Input
Label
The identifying label that will appear on the meter screen.
Units
The engineering units that the input voltage will be scaled to
represent.
scale values
The minimum and maximum input voltages and corresponding
engineering values.
5.
Press
OK.