Working basis
18
Service Instructions 878-M PREMIUM - 03.0 - 10/2019
Removing the valve cover
1.
Loosen the screws (2).
2.
Remove the valve cover (1).
Placing the valve cover
1.
Place the valve cover (1).
2.
Tighten the screws (2).
3.4.5
Disassembling and assembling the throat plate
Fig. 6: Disassembling and assembling the throat plate
Proper setting
At the standard setting the throat plate slide should be positioned at the
center of the throat plate.
Disassembling the throat plate and setting the position of the throat
plate slide
1.
Loosen the 2 screws (3).
2.
Remove the throat plate (4).
3.
Loosen the screws (2).
4.
Adjust the throat plate slide (1) at the center of the throat plate (4).
5.
Tighten the screws (2).
Assembling the throat plate
1.
Insert the throat plate (4).
2.
Tighten the 2 screws (3).
(1)
- Throat plate slide
(2)
- Screws
(3)
- Screws
(4)
- Throat plate
③
②
④
①
Summary of Contents for 878-M PREMIUM
Page 1: ...878 M PREMIUM Service Instructions...
Page 10: ...About these instructions 8 Service Instructions 878 M PREMIUM 03 0 10 2019...
Page 66: ...Integrated motor 64 Service Instructions 878 M PREMIUM 03 0 10 2019...
Page 114: ...Maintenance 112 Service Instructions 878 M PREMIUM 03 0 10 2019...
Page 116: ...Decommissioning 114 Service Instructions 878 M PREMIUM 03 0 10 2019...
Page 118: ...Disposal 116 Service Instructions 878 M PREMIUM 03 0 10 2019...
Page 126: ...Technical data 124 Service Instructions 878 M PREMIUM 03 0 10 2019...
Page 127: ...Appendix Service Instructions 878 M PREMIUM 03 0 10 2019 125 23 Appendix Wiring diagram...
Page 128: ...Appendix 126 Service Instructions 878 M PREMIUM 03 0 10 2019...
Page 129: ......