3-8
Control panel
Status
color
Alarm
lamp
Alarm
lamp
behaviour
Description/Action
Status
color
Stack light
Stack light
behaviour
Red
flashing
•
Serious condition that might result in an
incomplete process. In some situations
the process will stop immediately.
•
If ignored in severe situations, it might
also result in damage of the processor.
•
Processing is not possible.
•
Operator will be prompted for immediate
action.
•
Confirmation of alarm is required when
cause of the alarm has been removed.
•
Initialization is needed after confirmation
of alarm.
Red steady
Alarms view
By pressing the 'Alarm' button in any view, a
complete list of the present alarms will be
displayed.
Use the buttons in the right side of the display to
navigate between the alarms:
-
Scroll up / down
-
Clear alarm
-
Alarm history
(see example
below)
Alarm codes
All alarms has a numeric code. For more information of each alarm and relevant actions/remedies, look up
the alarm code in the "Alarm list" on page A-1.
The alarm codes may also be useful information to a service technician when service assistance is
required.
Operation Manual
|
Cyrel FAST 2000TD
January, 2020
Summary of Contents for Cyrel FAST 2000TD
Page 37: ...Operation procedures 2 19 Blank January 2020 Operation Manual Cyrel FAST 2000TD...
Page 38: ...3 0 Panel overview Panel overview Operation Manual Cyrel FAST 2000TD January 2020...
Page 49: ...Control panel 3 11 Menu diagram January 2020 Operation Manual Cyrel FAST 2000TD...
Page 86: ...Operation Manual Cyrel FAST 2000TD January 2020...
Page 106: ...B 14 Appendix B Blank Operation Manual Cyrel FAST 2000TD January 2020...