Maintenance
Threading of nonwoven (NW), PET and waste
New thread of nonwoven, PET, and waste will be necessary after e.g. a web rupture. Follow the
descriptions below for correct threading of the nonwoven, PET and waste.
WARNING:
Always pay attention to the warning labels on the equipment and take appropriate
precautions for each potential hazard.
WARNING:
Refer to the "Safety precautions" on page 0-9 and the separate Safety Instruction
Manual part No 21741 .
WARNING:
Please wear your personal safety protection, e.g. safety shoes and heat protection
gloves.
Tools required
•
Pair of scissors or stanley knife.
•
Double-side self-adhesive heat resistant tape (e.g. Tesa 4965 (50mm/2"), heat resistant up to 200 °C
transient/100 °C prolonged).
•
Strong duct tape 50 mm wide.
Procedure
1.
Press the ON/OFF if light blue, indicating that
Power (heat) is turned on. If dark blue continue
with step 4.
2.
Then press the 'Heating - Power OFF' button
to switch the heating off.
WARNING:
This procedure must
ONLY
be done on a cool machine!
The heated roller is very hot: greater than 150°C (302°F), and the Catox enclosure is approx. 50°C
(122°F)! Wait for the equipment to cool down automatically before continuing.
3.
While waiting for the processor to cool down, prepare the tools needed, the rolls, the Translyft (or
other lifting devicefor lifting of the heavy rolls).
4.
Open the rear cover.
5.
Remove the left side panel.
Operation Manual
|
Cyrel FAST 2000TD
January, 2020
Summary of Contents for Cyrel FAST 2000TD
Page 37: ...Operation procedures 2 19 Blank January 2020 Operation Manual Cyrel FAST 2000TD...
Page 38: ...3 0 Panel overview Panel overview Operation Manual Cyrel FAST 2000TD January 2020...
Page 49: ...Control panel 3 11 Menu diagram January 2020 Operation Manual Cyrel FAST 2000TD...
Page 86: ...Operation Manual Cyrel FAST 2000TD January 2020...
Page 106: ...B 14 Appendix B Blank Operation Manual Cyrel FAST 2000TD January 2020...