4-2
Maintenance
What
Description
Frequence
Notes
Chiller. Level of
temperature and
antifreeze
solution.
Make a visual check of the
temperature level. Ensure that the
temperature set point is 17 °C by
pressing the Set button on the
chiller controller.
Make a visual check of the level
of antifreeze. The level is shown
in the level indicator on the front
of the chiller unit. Level must be
max. or almost max.
Daily
Contact trained operator if any of
the levels are incorrect.
Clean the
processor.
Clean windows, panels and
covers with a moist cloth and a
mild household cleaning solution.
1 week
Do not use aggressive solvents
as this could damage the
processor covers.
Check the correct
operation of the
emergency stop
buttons and cover
interlocks.
Actuate all emergency stop
buttons and check for correct
function = Messages must
appear on the control panel and
stack light must turn red.
Open all interlocked covers and
check for correct function =
Messages must appear on the
control panel and stack light must
turn red.
1 month
Refer to "Emergency stops" on
page 0-10. If any operations fail
call a service technician.
WARNING:
Do not use
the processor unless ALL
the safety devices are
fully operational.
Cleaning the air
filter.
The moisture and dirt filter in the
air filter should be checked and
cleaned.
3 months
This operation has to be carried
out with the supply for
compressed air switched off.
Service reminders
The machine displays periodic maintenance reminders for: General Service, Oil Change and Grease
Cartridge replacement. This is to ensure the correct maintenance schedule is applied to the machine:
Each message is displayed in a separate pop up box (an example is shown above) and needs to be
acknowledged separately. Any combination of all 3 messages can be displayed at one time (1, 2 or all 3).
To acknowledge the reminders, select OK. When the service reminders are displayed please contact
your local DuPont Service or local DuPont representative to organise a service visit immediately.
WARNING:
It is very important that a service visit is organised the first time any one of the
reminders is displayed. Failure to do this immediately could seriously damage the machine and
invalidate any warranty on the machine.
Operation Manual
|
Cyrel FAST 2000TD
January, 2020
Summary of Contents for Cyrel FAST 2000TD
Page 37: ...Operation procedures 2 19 Blank January 2020 Operation Manual Cyrel FAST 2000TD...
Page 38: ...3 0 Panel overview Panel overview Operation Manual Cyrel FAST 2000TD January 2020...
Page 49: ...Control panel 3 11 Menu diagram January 2020 Operation Manual Cyrel FAST 2000TD...
Page 86: ...Operation Manual Cyrel FAST 2000TD January 2020...
Page 106: ...B 14 Appendix B Blank Operation Manual Cyrel FAST 2000TD January 2020...