2-10
Operation procedures
Stopping a processing job
The reason for manual ejection could be:
•
Incorrect plate parameters have been entered into 'Job selection'. When realizing this, the plate must
be ejected to avoid potential damage to the plate and/or the processor.
•
A visual check through the window in the top cover reveals that the plate has not been loaded
correctly and thus must be ejected.
•
A visual check through the window in the top cover reveals that part of the plate is not correctly
attached to the front or rear clamp arm pins. The plate must be ejected to avoid further damage of the
plate.
•
Other reasons for need of manual ejection could be; emergency stop has been activated, top, front, or
rear covers have been opened during processing, or an alarm which requires ejection/removal of the
plate.
If for some reason you need to stop a processing job, please refer to the "Manual eject function
(interrupting processing)" on page 2-13.
Restarting a processing job
See also description of "Stopping a processing job" on page 2-10.
If a plate has been ejected before all the programed cycles have been completed, and you wish to finish
the processing cycle, you can enter the cycle number from which you want to resume the process.
Normally you should enter the cycle number that was about to start, when the plate was ejected. Then re-
insert the plate and press the 'Start' button in order to complete processing of the plate.
Operation Manual
|
Cyrel FAST 2000TD
January, 2020
Summary of Contents for Cyrel FAST 2000TD
Page 37: ...Operation procedures 2 19 Blank January 2020 Operation Manual Cyrel FAST 2000TD...
Page 38: ...3 0 Panel overview Panel overview Operation Manual Cyrel FAST 2000TD January 2020...
Page 49: ...Control panel 3 11 Menu diagram January 2020 Operation Manual Cyrel FAST 2000TD...
Page 86: ...Operation Manual Cyrel FAST 2000TD January 2020...
Page 106: ...B 14 Appendix B Blank Operation Manual Cyrel FAST 2000TD January 2020...