B-12
Appendix B
4.
The chiller is to be filled with a mixture of clean water and anti-freeze. The specification for the anti-
freeze is:
5.
Use only antifreeze type; G12+, G12++, or G13. For the USA please use a propylene glycol based
anti-freeze. Caution: Do NOT mix anti-freeze types!
CAUTION:
The capacity of the chiller is 5 the capacity of hoses and heat exchangers.
Therefore please have available 5 Litres of anti-freeze which when diluted to 15~20% will provide
up to 30 Litres of ready mixed coolant.
6.
If the coolant level was low during operation, the alarm “AL01; Low tank level", which stops the
pump operation will have been activated.
7.
Reset the “AL01; Low tank level". Press the [RESET] key ([▼] and [▲] keys simultaneously) to
stop the alarm buzzer.