Description of Controls
Page 87 of 188
057-254 ISSUE: 2
NOTE: For further details, see section entitled Operation elsewhere in this manual.
Icon
Description
Alarm Mute / Lamp Test
This button silences the audible alarm in the controller, de-activates the Audible
Alarm output (if configured) and illuminates all of the LEDs on the module’s facia
as a lamp test function.
Start
This button is only active in the Stop/Reset Mode
, Manual Mode
Pressing the Start
button in Stop/Reset Mode
powers up the engine’s
ECU but does not start the engine. This can be used to check the status of the
CAN communication and to prime the fuel system.
Pressing the Start
button in Manual Mode
starts the generator and runs it
off load in Manual Mode
Menu Navigation
Used for navigating the instrumentation, event log and configuration screens.
Close Generator
The Close Generator
button controls the operation of the generator load
switch and is only active in the Manual Mode
once the generator is available.
Pressing the Close Generator
button when the generator is available and off
load automatically instructs the generator to synchronise and once in sync, to be
place the generator on load (‘Close Generator Output’ becomes active). If the
generator bus is dead (has not supply on it) the generator is placed on load
immediately. Further presses of the Close Generator
button have no effect.
Open Generator
The Open Generator
button is only active in the Manual Mode
and
allows the operator to open the generator load switch.
Pressing the Open Generator
button when the Generator is on load,
automatically ramps the load off the generator and then takes it off load (‘Close
Generator Output’ becomes inactive). Further presses of the
Open Generator
button have no effect.
Summary of Contents for 8610 MKII
Page 63: ...Installation Page 63 of 188 057 254 ISSUE 2 3 4 2 SINGLE PHASE L1 N 2 WIRE WITHOUT EARTH FAULT...
Page 69: ...Installation Page 69 of 188 057 254 ISSUE 2 3 4 8 2 PHASE L1 L2 3 WIRE WITHOUT EARTH FAULT...
Page 71: ...Installation Page 71 of 188 057 254 ISSUE 2 3 4 10 2 PHASE L1 L3 3 WIRE WITHOUT EARTH FAULT...
Page 72: ...Installation 057 254 ISSUE 2 Page 72 of 188 3 4 11 3 PHASE 3 WIRE DETLA WITHOUT EARTH FAULT...
Page 187: ...This Page is Intentionally Blank...
Page 188: ...This Page is Intentionally Blank...