DResearch GmbH – Configuration of the Hydra
IP
analogue DVR
2011-02-02
19
3.3
Recording
Parameter
Recordings – Definition of records
Camera/Source
The source of data (camera, microphones) that is used to record single tracks (Archive)
with. This field is not editable. The labels can be changed through the previous tab
Track ID
The tracks that are used for the system internal recording. This field is not editable.
Video input
The physical interface that the source is connected to. This field is not editable.
Ring recording
duration
Setting the duration for the ring recording. The recording duration is given in hours and
refers to the actual recording time of the system. 72 hours is the default value. The
oldest data is automatically overwritten should the specified value be higher and the
capacity of the data storage medium not sufficient.
Recommended setting: 72 hours
Archive configuration and disposal of recorded data.
There is an entry for every source.
Configurable digital inputs GPI for controlling the
recordings. In this illustration, the configuration of a
Master/Slave system MR306-6 is opened. In this case, the
cameras of the slave, on the right, are configurable. (Only
with M/S)