DResearch GmbH – Configuration of the Hydra
IP
analogue DVR
2011-02-02
10
2.1.4
Launching the configuration application and editing the configuration set
After you have downloaded the configuration set from the system, you can begin to edit it. Insert the
configuration flash drive into the configuration PC and launch the configuration application on the flash
drive:
Remove the flash drive after successful download (see LED codes) from the system
Connect the flash drive to your PC and open the file configApp.html with a web browser
(confirm access to the file system, as well as the execution of ActiveX components)
Choose a configuration and open it for editing
NOTE:
You have to confirm access to the file system through the browser, during the start of the
configuration application (configApp.html). It is necessary to enable the execution of ActiveX
components, if Internet Explorer is used. Note that the Java Script functions of your web browser
have to be enabled.
An overview of all systems will open after the launch of the configuration application. You will find a list
of default configurations for all DVR systems, after the creation of a new configuration flash drive. If
you are using an existing configuration flash drive, all systems will be listed that have been edited with
this flash drive.
Every system functions with an internally stored configuration set. Three different configuration sets
are managed by the configuration application:
ORIGINAL
This is the configuration set stored on the DVR. It is automatically
saved to the USB flash drive (download) when connected to the
system.
EDITING
The configuration set to be edited. This set is provided as an editable
version after selection of a DVR configuration (a copy of the
ORIGINAL set). This set can be changed at will.
RELEASE
This set is released for upload, upon completion of changes. Only this
set is transferred to the device, when connecting the configuration
flash drive to the DVR.