Communications
Parameter
Communication – Configuration IBIS vehicle bus
Currently, only the communication over the IBIS vehicle bus is configurable at this point. At a later time,
the configuration for data transfer and GPS-data recording will be provided in this part.
DVR is a IBIS Client The system works in accordance with the IBIS Standard VDV300 and can be integrated
as a cancellation unit, display unit or announcement unit into the vehicle bus (020, 030,
070).
IBIS Client Address
Specification of the client-address that the system contains within the IBIS-Bus. It should
be clarified which IBIS-Addresses are available for use in the vehicles. The possible
choices depend on the specified client-type.
IBIS Error Timeout
Time interval (in seconds)
in
which, after the start of the system, IBIS-Errors are not
interpreted and/or reported. Usually the HydraIP systems start a lot faster than the IBIS-
Board computer of the vehicle. In this case, the system would document an IBIS error, if
the board computer hasn’t sent any data yet. The error messages can be disabled in this
time period.
Recommended setting: 300 Seconds