2.1.3
Down and upload of the configuration set to/from the system
Download the configuration set from the system
After successfully downloading the configuration set, the process can begin on the configuration PC.
To download the configuration set from the DVR, do the following:
Take the configuration flash drive and connect it to the DVR
Wait until download has finished (LED lights flash green)
Remove the flash drive from the DVR and connect it to the configuration PC
Start the configuration application (configApp.html). You will find the file in the root folder of
the flash drive.
Upload of configuration set to the system
The edited configuration set will be saved automatically on the flash drive, after RELEASE and
prepared for upload to the system. Remove the USB flash drive from the configuration PC and
connect it to the system
The system will automatically recognize the configuration set and start the upload
Remove the flash drive after the upload process has finished. The system will reboot, load the
new configuration set and start with the new settings
NOTE:
If the system signals a configuration error after reboot (LED STATE = red, ERROR = orange flash),
the new configuration set failed to load. Possible causes could be: An outdated firmware version
(firmware and configuration are incompatible) or the configuration set contains incorrect entries.
In this case, try to edit the configuration again, save it and reload it to the system. At the same time,
you should do a firmware update with the most current firmware. If the problem persists, contact
customer service