OP000599
Inspection, Maintenance and Adjustment
4-60
AIR-CONDITIONING SYSTEM
NOTE:
See “Clean Air-Conditioning Outer Filter” on
page 4-38.
Check Control Panel
When a function switch is pushed, the last setting has to be
displayed on the LCD display.
When the light switch is turned to "I" position, the LED for
illumination in the control panel has to turn "ON."
Check Air Conditioner Hoses
Check the hose for cracking and damage.
Check Condenser
Inspect the condenser for dust and debris. Clean if necessary.
NOTE:
Check Magnetic Clutch
Check the magnetic clutch for dirt and interference.
Push the "A/C" switch in order to energize magnetic clutch and
check the magnetic clutch.
Check Belt Tension
NOTE:
See “Check Engine Fan Belt Tension” on page 4-32.
CAUTION!
When a leak occurs, dirt will accumulate in the area where
the leak is. Consult a
DOOSAN
distributor or sales agency.