OP000598
Operation
3-20
OPERATING INSTRUCTIONS
Engine Speed Control
Engine speed can be manually adjusted using the engine speed
control dial, Increase engine speed by rotating the control knob
clockwise. Decrease engine speed by rotating the control knob
counterclockwise.
Mode Selection
More efficient work can be done by choosing a proper power
and work mode combination, suitable to type of work and
conditions. Use the mode selection according to following guide.
Power Mode
1.
When the starter switch is turned "ON" the power mode is
automatically defaulted to the standard setting.
2.
Select a proper power mode using button (1, Figure 40)
before starting work.
3.
When the power mode button (1, Figure 40) is pressed, a
signal sounds, changing the power mode to either "ON" or
"OFF." When the power mode is turned "ON," the LED
indicator (2, Figure 40) turns "ON."
Deactivate the power mode by pressing it a second time.
When the power mode is turned "OFF," the LED indicator
(2, Figure 40) turns "OFF" and the power mode returns to
the standard mode.
HAOA690L
Figure 39
IMPORTANT
The engine speed control system has been set at the
factory and should not require adjustment as part of routine
maintenance.
Figure 40
6
5
2
1
2
1
FG000114
Mode
Selection Point
STANDARD MODE
• General work.
• Minimize fuel consumption.
POWER MODE
• Required to perform heavy work in a short period of time.
• Fast speed loading.
• Fast speed travel.
Summary of Contents for DX140LC
Page 2: ......
Page 67: ...OP000597 2 3 Operating Controls ...
Page 87: ...OP000597 2 23 Operating Controls ...
Page 122: ...OP000597 Operating Controls 2 58 CD Player Optional AST DIR FG000109 Figure 123 ...
Page 184: ...OP000598 Operation 3 48 ...
Page 193: ...OP000599 4 9 Inspection Maintenance and Adjustment ...
Page 272: ...OP000599 Inspection Maintenance and Adjustment 4 88 ...
Page 278: ...OP000600 Transportation 5 6 ...
Page 284: ...OP000013 Troubleshooting 6 6 ...
Page 292: ...OP000601 Specification 7 8 ...