10. Fill the hydraulic oil tank. Check level using sight gauge on
side of tank.
11. Place spring (3, Figure 100) on rod (4) and assemble cover
(2).
12. After replacing and cleaning the hydraulic oil, filter and
strainer, vent the system. See “Venting and Priming
Hydraulic System” on page 4-84.
13. Check level of hydraulic oil tank. (See page 4-15)
Check Alternator and Starter**
**These checks need to be completed by an authorized
DOOSAN
dealer.
Check All Rubber Antivibration Shock
Mounts
Perform and Record the Results of the
Cycle Time Tests
Inspect Machine to Check for Cracked or
Broken Welds or other Structural
Damage
Check, Adjust Valve Clearance **
Check Head Bolt Torques
1
2
3
4
5
6
ARO1720L
Figure 100
IMPORTANT
When the hydraulic breaker is being used, due to the
higher heat generated by this unit, use replacement
intervals recommended under the “Hydraulic Oil and
Filter Service Intervals” on page 3-38.