Configurable Safety System SAFEMASTER PRO
18
0265525 / 16.05.19 en / 101A
Connection Terminals Control unit UG 6911.10
Connection Terminals Control unit UG 6911.12/080
TERMINAL
SIGNAL
TYPE
DESCRIPTION
OPERATION
1
24VDC
-
24 V DC power supply
-
2
MASTER_ENABLE1
Input
Master Enable 1
Input („Type 2“ acc. to EN 61131-2)
3
MASTER_ENABLE2
Input
Master Enable 2
Input („Type 2“ acc. to EN 61131-2)
4
0VDC
-
0 V DC power supply
-
5
OSSD1_A
Output
Static output 1
PNP active high
6
OSSD1_B
Output
PNP active high
7
RESTART_FBK1
Input
Feedback / Restart 1
Input („Type 2“ acc. to EN 61131-2)
8
OUT_STATUS1
Output
Programmable signal output
PNP active high
9
OSSD2_A
Output
Static output 2
PNP active high
10
OSSD2_B
Output
PNP active high
11
RESTART_FBK2
Input
Feedback / Restart 2
Input („Type 2“ acc. to EN 61131-2)
12
OUT_STATUS2
Output
Programmable signal output
PNP active high
13
OUT_TEST1
Output
Short circuit detection output
PNP active high
14
OUT_TEST2
Output
Short circuit detection output
PNP active high
15
OUT_TEST3
Output
Short circuit detection output
PNP active high
16
OUT_TEST4
Output
Short circuit detection output
PNP active high
17
INPUT1
Input
Digital input 1
Input („Type 2“ acc. to EN 61131-2)
18
INPUT2
Input
Digital input 2
Input („Type 2“ acc. to EN 61131-2)
19
INPUT3
Input
Digital input 3
Input („Type 2“ acc. to EN 61131-2)
20
INPUT4
Input
Digital input 4
Input („Type 2“ acc. to EN 61131-2)
21
INPUT5
Input
Digital input 5
Input („Type 2“ acc. to EN 61131-2)
22
INPUT6
Input
Digital input 6
Input („Type 2“ acc. to EN 61131-2)
23
INPUT7
Input
Digital input 7
Input („Type 2“ acc. to EN 61131-2)
24
INPUT8
Input
Digital input 8
Input („Type 2“ acc. to EN 61131-2)
TERMINAL
SIGNAL
TYPE
DESCRIPTION
OPERATION
1
24VDC
-
24 V DC power supply
-
2
NC
-
-
-
3
NC
-
-
-
4
0VDC
-
0 V DC power supply
-
5
OSSD1
Output
Static output 1
PNP active high
6
OSSD2
Output
Static output 2
PNP active high
7
RESTART_FBK1/
STATUS1
Input/
Output
Feedback / Restart 1
Input („Type 2“ acc. to EN 61131-2)
Programmable signal output
PNP active high
8
RESTART_FBK2/
STATUS2
Input/
Output
Feedback / Restart 2
Input („Type 2“ acc. to EN 61131-2)
Programmable signal output
PNP active high
9
OSSD3
Output
Static output 3
PNP active high
10
OSSD4
Output
Static output 4
PNP active high
11
RESTART_FBK3/
STATUS3
Input/
Output
Feedback / Restart 3
Input („Type 2“ acc. to EN 61131-2)
Programmable signal output
PNP active high
12
RESTART_FBK4/
STATUS4
Input/
Output
Feedback / Restart 4
Input („Type 2“ acc. to EN 61131-2)
Programmable signal output
PNP active high
13
OUT_TEST1
Output
Short circuit detection output
PNP active high
14
OUT_TEST2
Output
Short circuit detection output
PNP active high
15
OUT_TEST3
Output
Short circuit detection output
PNP active high
16
OUT_TEST4
Output
Short circuit detection output
PNP active high
17
INPUT1
Input
Digital input 1
Input („Type 2“ acc. to EN 61131-2)
18
INPUT2
Input
Digital input 2
Input („Type 2“ acc. to EN 61131-2)
19
INPUT3
Input
Digital input 3
Input („Type 2“ acc. to EN 61131-2)
20
INPUT4
Input
Digital input 4
Input („Type 2“ acc. to EN 61131-2)
21
INPUT5
Input
Digital input 5
Input („Type 2“ acc. to EN 61131-2)
22
INPUT6
Input
Digital input 6
Input („Type 2“ acc. to EN 61131-2)
23
INPUT7
Input
Digital input 7
Input („Type 2“ acc. to EN 61131-2)
24
INPUT8
Input
Digital input 8
Input („Type 2“ acc. to EN 61131-2)