Configurable Safety System SAFEMASTER PRO
123
0265525 / 16.05.19 en / 101A
NETWORK IN
The function block NETWORK implements a Network
connection input interface; it generates an LL1 in the
OUT output when the line is high, otherwise an LL0.
Parameters
Input Type:
- Single: Enables the connection of signalling outputs of an additional UG 6911 unit
- Double: Enables the connection of OSSD outputs of an additional UG 6911 unit
Filter (ms):
Enables the filtering of signals from an additional UG6911 unit. This filter can be set to between 3 and 250 ms.
The length of the filter affects the calculation of the unit's total response time.
This input can only be allocated on UG 6911. This input must be used when UG6911 OSSD outputs are connected
to the inputs of a second downstream UG 6911 or together with the NETWORK operator.