Server Management
4-5
PRIO
RIS
XL
6000
POST Beep Codes
POST cannot display messages when an error occurs before the monitor is
initialized. Instead, it emits a beep code. The beep code is a series of individual
beeps, each equal in length. Write down any beep code for your authorized
service provider.
Beeps
Error Message
Error Message Conditions
1
Refresh failure
Memory refresh circuitry on the main logic board is
faulty.
2
ECC double-bit error
cannot be reset
ECC double-bit error in the first 64 KB memory.
3
Base 64 KB memory
failure
Memory failure in first 64 KB memory.
4
Timer not operational
Timer on main logic board not operational or
memory failure in first 64 KB memory.
5
Processor failure
Processor on main logic board generated an error.
6
Keyboard controller
gate A20 is off
BIOS cannot switch to protected mode. Keyboard
controller might be bad.
7
Processor exception
interrupt error
Processor exception interrupt error.
8
Display memory
read/write error
Video controller is missing or its memory is faulty
(not a fatal error).
9
ROM checksum error
ROM checksum value does not match encoded
value in BIOS.
10
Shutdown register
read/write error
Shutdown register for CMOS RAM failed.
Summary of Contents for Prioris XL 6000 Series
Page 36: ...Server Components 3 5 PRIORIS XL 6000 Figure 3 3 Server Front View...
Page 38: ...Server Components 3 7 PRIORIS XL 6000 Figure 3 4 Server Left Side View...
Page 40: ...Server Components 3 9 PRIORIS XL 6000 Figure 3 5 Server Rear View...
Page 42: ...Server Components 3 11 PRIORIS XL 6000 Figure 3 6 Main Logic Board Components and Connectors...
Page 58: ...Installing Additional Memory 5 5 PRIORIS XL 6000 Figure 5 2 Installing a DIMM...
Page 61: ...Installing Additional Memory 5 8 Figure 5 3 Installing a Video Memory Expansion Chip...
Page 74: ...Installing Expansion Boards 7 2 Figure 7 1 Expansion Board Slot Locations...
Page 91: ...Connecting SCSI Adapters 8 3 PRIORIS XL 6000 Figure 8 1 Single Channel SCSI Configuration...
Page 128: ...Field Service Replacement 11 17 PRIORIS XL 6000 Figure 11 7 Replacing the Battery...
Page 135: ...Field Service IPB 12 5 PRIORIS XL 6000 DEC01105...
Page 137: ...13 1 PRIORIS XL 6000 13 Field Service Notes 13...
Page 148: ...Technical Specifications A 7 PRIORIS XL 6000 Figure A 1 Main Logic Board Jumper Locations...