Field Service Replacement
11-10
Removing and Replacing the Drive Bay Cooling Fan
The following procedure can be used to remove the drive bay cooling fan.
1. Turn off the server.
2. Disconnect the ac power cord.
3. Unlock and remove the side panel.
4. Disconnect power and data cables from installed drives.
5. Remove and retain lower screw (A, Figure 11-4).
6. Loosen, but do not remove, the top screw that secures drive bay (B, Figure
11-4).
7. Slide down the locking bracket, but do not remove (C, Figure 11-4).
8. Swing the drive bay out.
9. Disconnect the fan cable from the main logic board.
10. Remove the drive bay.
11. Press the plastic tabs to release the fan from the fan housing.
12. Remove the fan from the fan housing.
13. Replace the fan by performing the removal steps in reverse order.
Summary of Contents for Prioris XL 6000 Series
Page 36: ...Server Components 3 5 PRIORIS XL 6000 Figure 3 3 Server Front View...
Page 38: ...Server Components 3 7 PRIORIS XL 6000 Figure 3 4 Server Left Side View...
Page 40: ...Server Components 3 9 PRIORIS XL 6000 Figure 3 5 Server Rear View...
Page 42: ...Server Components 3 11 PRIORIS XL 6000 Figure 3 6 Main Logic Board Components and Connectors...
Page 58: ...Installing Additional Memory 5 5 PRIORIS XL 6000 Figure 5 2 Installing a DIMM...
Page 61: ...Installing Additional Memory 5 8 Figure 5 3 Installing a Video Memory Expansion Chip...
Page 74: ...Installing Expansion Boards 7 2 Figure 7 1 Expansion Board Slot Locations...
Page 91: ...Connecting SCSI Adapters 8 3 PRIORIS XL 6000 Figure 8 1 Single Channel SCSI Configuration...
Page 128: ...Field Service Replacement 11 17 PRIORIS XL 6000 Figure 11 7 Replacing the Battery...
Page 135: ...Field Service IPB 12 5 PRIORIS XL 6000 DEC01105...
Page 137: ...13 1 PRIORIS XL 6000 13 Field Service Notes 13...
Page 148: ...Technical Specifications A 7 PRIORIS XL 6000 Figure A 1 Main Logic Board Jumper Locations...