Server Management
4-4
Server Status
Component
Possible Failures
Result
Main logic board
voltages: +12, +5,
+3.3, and -12V
The voltages are outside of the power
good range.
An error message displays and a
warning beep sounds.
The voltage exceeds the upper limit.
The server will shutdown after 5
minutes.
The voltage falls below the lower limit.
A warning message displays and
a warning beep sounds.
Fans 1 and 2
The fans fail.
The server will shutdown after 5
minutes.
CPU failure
A CPU failure:
•
Internal
•
Over temperature
An error message displays and a
warning beep sounds.
Usually caused by a fan failure
and the result is that the server
shuts down.
CPUtemperature
sensing
The temperature exceeds 82 °C
(179.6 °F).
The backup fans will activate
without any warning.
If the temperature drops below 80
°C (176 °F), the backup fans will
be turned off.
The temperature exceeds the warning
level (>85 degrees C; >185 °F).
A warning message displays and
a warning beep sounds. If the
temperature exceeds the warning
level for more than five minutes,
the server will shut down.
The temperature exceeds the upper
limit (>90 °C; >194 °F).
The server will shut down.
Power supply failure
The temperature exceeds the upper
limit or the voltages are out of range.
Power supply shuts down, an error
message displays, and a beep
sounds.
Summary of Contents for Prioris XL 6000 Series
Page 36: ...Server Components 3 5 PRIORIS XL 6000 Figure 3 3 Server Front View...
Page 38: ...Server Components 3 7 PRIORIS XL 6000 Figure 3 4 Server Left Side View...
Page 40: ...Server Components 3 9 PRIORIS XL 6000 Figure 3 5 Server Rear View...
Page 42: ...Server Components 3 11 PRIORIS XL 6000 Figure 3 6 Main Logic Board Components and Connectors...
Page 58: ...Installing Additional Memory 5 5 PRIORIS XL 6000 Figure 5 2 Installing a DIMM...
Page 61: ...Installing Additional Memory 5 8 Figure 5 3 Installing a Video Memory Expansion Chip...
Page 74: ...Installing Expansion Boards 7 2 Figure 7 1 Expansion Board Slot Locations...
Page 91: ...Connecting SCSI Adapters 8 3 PRIORIS XL 6000 Figure 8 1 Single Channel SCSI Configuration...
Page 128: ...Field Service Replacement 11 17 PRIORIS XL 6000 Figure 11 7 Replacing the Battery...
Page 135: ...Field Service IPB 12 5 PRIORIS XL 6000 DEC01105...
Page 137: ...13 1 PRIORIS XL 6000 13 Field Service Notes 13...
Page 148: ...Technical Specifications A 7 PRIORIS XL 6000 Figure A 1 Main Logic Board Jumper Locations...