Installing Additional Memory
5-6
Memory Troubleshooting
The Prioris XL 6000 Series server POST can detect memory errors when it
boots. The error can be isolated to one of the DIMMs installed on the main logic
board.
The memory error message format is as follows:
<Type of <Error>: <Location>
Where:
<Type of Error>
Correctable error
Uncorrectable error
<Location>
Main logic board
DIMM 0
Main logic board
DIMM 1
Main logic board
DIMM 2
Main logic board
DIMM 3
Example:
Uncorrectable Error : Main Logic Board DIMM 0
If a correctable error occurs, the BIOS will display: “Press <F1> to resume” after
the server boots.
If an uncorrectable error occurs, the server will halt after the memory test.
To isolate to the failing DIMM, replace one of the DIMMs which was indicated in
the POST error message with a similar DIMM and then rerun POST. If the
same error message occurs, replace the DIMM.
Summary of Contents for Prioris XL 6000 Series
Page 36: ...Server Components 3 5 PRIORIS XL 6000 Figure 3 3 Server Front View...
Page 38: ...Server Components 3 7 PRIORIS XL 6000 Figure 3 4 Server Left Side View...
Page 40: ...Server Components 3 9 PRIORIS XL 6000 Figure 3 5 Server Rear View...
Page 42: ...Server Components 3 11 PRIORIS XL 6000 Figure 3 6 Main Logic Board Components and Connectors...
Page 58: ...Installing Additional Memory 5 5 PRIORIS XL 6000 Figure 5 2 Installing a DIMM...
Page 61: ...Installing Additional Memory 5 8 Figure 5 3 Installing a Video Memory Expansion Chip...
Page 74: ...Installing Expansion Boards 7 2 Figure 7 1 Expansion Board Slot Locations...
Page 91: ...Connecting SCSI Adapters 8 3 PRIORIS XL 6000 Figure 8 1 Single Channel SCSI Configuration...
Page 128: ...Field Service Replacement 11 17 PRIORIS XL 6000 Figure 11 7 Replacing the Battery...
Page 135: ...Field Service IPB 12 5 PRIORIS XL 6000 DEC01105...
Page 137: ...13 1 PRIORIS XL 6000 13 Field Service Notes 13...
Page 148: ...Technical Specifications A 7 PRIORIS XL 6000 Figure A 1 Main Logic Board Jumper Locations...