OPERATOR’S MANUAL
Control Point
®
11001-1489-201702 Rev B
46 / KEYBOARD PROGRAMMING
Figure 31
Configuring the Granular Channel
Check each following item for a desired setting.
–
SPR CON
(Spreader Constant) – Represents the number of pulses
generated by the application rate sensor per pound of material (P/
LB) discharged from the spreader.
The spreader constant differs for each granular material, spreader
vehicle, and gate height setting. If the spreader constant is known,
keyboard enter the value so that running the GRANULAR
CALIBRATION routine for this material is unnecessary. If the
spreader constant is unknown, leave the displayed value. The
correct value is automatically corrected later, during GRANULAR
CALIBRATION.
– CAL GT HGT
(Calibration Gate Height) - Displayed only if optional
Gate Height Sensor is Enabled. If Enabled, the Calibration Gate
Height valve displayed is the setting of the gate height in inches
when the spreader was calibrated. Refer to page 77 for the
Spreader Calibration procedure.
Changing the original calibrated gate setting by adjusting the
conveyor speed provides a more accurate granular material
application. Increased Gate Height decreases conveyor speed;
Decreased Gate Height increases conveyor speed.
–
DRV FREQ
(Drive Frequency) – Represents the valve
manufacturer’s suggested drive frequency, as shown on the valve
specification sheet.
CONFIGURATION
SELECT A MENU ITEM
1 SALT ENABLED
2 SAND DISABLED
3 MIX A DISABLED
4 MIX B DISABLED
Press Function Key F3
(GRANULAR CONFIG)
SALT CONFIGURATION
SPR
CON
80.0
P/LB
CAL GT HGT
7.4
IN
DRV
FREQ
100
HZ
PWM OFFSET
14
PWM SAT
70
SYS RSPNS
11.25
VALV BOOST
2.0
AFILT
0.250000
Summary of Contents for Control Point
Page 1: ...CONTROL POINT CONTROL SYSTEM Operator s Manual SINCE 1966 ...
Page 5: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B IV ...
Page 7: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 2 SAFETY NOTICES ...
Page 13: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 8 INTRODUCTION ...
Page 29: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 24 START UP AND FAMILIARIZATION ...
Page 77: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 72 KEYBOARD PROGRAMMING ...
Page 79: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 74 SYSTEM CALIBRATION ...
Page 91: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 86 SYSTEM CALIBRATION ...