OPERATOR’S MANUAL
Control Point
®
11001-1489-201702 Rev B
50 / KEYBOARD PROGRAMMING
Figure 33
Setting Granular Application Rates (Rate Method)
LIQUID CONFIGURATION SETUP (F5)
Configuration parameters specify types of actuators and sensors used
including performance specifications. To prepare for system calibration, the
liquid configuration parameters for each liquid material used must be
verified or programmed. These parameters do not change unless system
hardware changes or related calibration routines are rerun.
1. From the keyboard, press Function key F5 to obtain the LIQUID
CONFIG screen, refer to (
). Four (4) liquid material names
appear with the option to ENABLE or DISABLE. Products are enabled/
disabled from the LIQUID APPL RATE screen (F4).
SETTING LIQUID CONFIGURATIONS
2. Select a material using the corresponding number key.
APPLICATION RATE
SELECT A MENU ITEM
1 SALT ENABLED
2 SAND DISABLED
3 MIX A DISABLED
4 MIX B DISABLED
Press Function Key F2
(GRANULAR APPL RATE)
SALT APP RATES
ENABLE
YES
STEP METHD
NO
RATE 1
100 LBS / MILE
RATE 2
200 LBS / MILE
RATE 3
300 LBS / MILE
RATE 4
400 LBS / MILE
RATE 5
500 LBS / MILE
RATE 6
600 LBS / MILE
MORE . . .
SALT APP RATES
MORE . . .
RATE 7
700 LBS / MILE
RATE 8
800 LBS / MILE
RATE 9
900 LBS / MILE
RATE 10
1000 LBS / MILE
BLST RATE
1200 LBS / MILE
CHNL LBL
SALT
Summary of Contents for Control Point
Page 1: ...CONTROL POINT CONTROL SYSTEM Operator s Manual SINCE 1966 ...
Page 5: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B IV ...
Page 7: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 2 SAFETY NOTICES ...
Page 13: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 8 INTRODUCTION ...
Page 29: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 24 START UP AND FAMILIARIZATION ...
Page 77: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 72 KEYBOARD PROGRAMMING ...
Page 79: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 74 SYSTEM CALIBRATION ...
Page 91: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 86 SYSTEM CALIBRATION ...