and liquid 2 anti-ice, the tank level will only display when the switch is
in prewet mode. If the switch is in anti-ice mode, the tank level will not
display.
If the tank level is set for liquid 2, enable tank level under the liquid 2
configuration screen. This will disable the tank level on liquid 1. When
the tank level is enabled, a bar graph with a digital percentage readout
(bargraph YES) or an approximate material remaining readout will
display (bargraph NO). If granular is enabled, the spinner bar graph will
share its portion of the Operate screen with the tank level. If the tank
level is disabled, the spinner bar graph will display across the lower
section of the Operate screen.
ENABLING TANK LEVEL SENSOR
6. Press Function key F5 Liquid Configuration and select a material 1-4.
The default for Tank Level is NO. When Tank Level is changed to
YES, the text PRESS C TO CAL TANK LEVEL appears at the bottom
of the screen. Press C to begin calibration. When complete, press D
or Escape key (refer to Figure 35).
TANK EMPTY AND TANK FULL
Both the Tank Empty and Tank Full values can be entered manually or
automatically captured.
Manual Entry
: Select the Tank Empty text and enter the empty voltage from
the manufacturer’s specifications.
Automatic Entry:
Verify the tank is empty and the sensor is installed and
connected. Select the Tank Empty text and Press “C” to capture the sensor
voltage.
TANK ALARM
The Tank Alarm is a user-definable value that informs the driver when the
tank level has reached the alarm limit. The value has a 5% hysteresis
tolerance to prevent random alarming due to varying tank levels while
driving.
Example 1:
If the Tank Alarm is set for 10%, the alarm will activate when the
level drops below 10%, but will not be cleared until the level reaches 15%).
Example 2:
If the Tank Alarm is set for 100 gallons on a 1000 gallon
capacity, the alarm will activate when the level drops below 100 gallons, but
will not be cleared until the level reaches 150 gallons).
The alarm will sound for the first five seconds, then the text will flash on the
screen until the condition is cleared or another alarm is issued.
Summary of Contents for Control Point
Page 1: ...CONTROL POINT CONTROL SYSTEM Operator s Manual SINCE 1966 ...
Page 5: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B IV ...
Page 7: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 2 SAFETY NOTICES ...
Page 13: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 8 INTRODUCTION ...
Page 29: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 24 START UP AND FAMILIARIZATION ...
Page 77: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 72 KEYBOARD PROGRAMMING ...
Page 79: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 74 SYSTEM CALIBRATION ...
Page 91: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 86 SYSTEM CALIBRATION ...