14-12
ID-04 Imager User’s Manual
Output Filter Configuration
Data
Important:
The ASCII characters
<
,
>
, and
,
can only be entered as hex pairs:
For
<
:
<K744h,,,,,,3C>
For
>
:
<K744h,,,,,,3E>
For
,
:
<K744h,,,,,,2C>
See
ASCII Character Entry Modifier
for a detailed explanation of how to
enter ASCII characters as hex values.
Database Index
Definition:
This is the data string to be used when comparing symbol data for output
filtering and ordering. This data string may also contain wildcard and
placeholder characters to facilitate matching. Remember that in order to
filter or order symbol data, it must meet all the requirements of the
selected filter index.
Examples:
• Filter data = “123*”. This will match data strings of “123”, “123456”, and
“123ABC”, but not “12”.
• Filter data = “123*AB?C”. This will be interpreted as “123*”.
• Filter data = “123?”. This will match “1234” and “123A”, but not “123”,
“12345”, or “1234C”.
• Filter data = “123?A”. This will match “1234A” and “123BA”, but not
“123”, “1234C”, or “1234ABCD”.
• Filter data = “123?A?”. This will match “1234AB” and “123BAT”, but not
“1234A” or “123BATS”.
• Filter data = “12??*”. This will match “1234”, “123456”, and “123ABC”,
but not “12” or “123”.
• Filter data = “123?A*”. This will match “1234A”, “123BA”, and
“123BATS”, but not “1234” or “1234C”.
Serial Cmd:
<
K744,
filter number,symbology type,length,wildcard,placeholder,
data
,
unused,database index>
Default:
00
(
NUL
)
Options:
Any ASCII input in the form of a pair of hex characters.
Maximum length: 63 bytes defined.
Data [0] =
NUL
represents string matching disabled.
Definition:
The index of the database entry that decodes a given symbol must equal
this setting for filtering to occur. A setting of
0
allows any database index for
this filter entry.
Serial Cmd:
<
K744,
filter number,symbology type,length,wildcard,placeholder,data,
unused,
database index
>
Default:
0
(any index)
Options:
0 to 10
Summary of Contents for ID-04
Page 1: ...ID 04 Imager User s Manual ID 04 User s Manual ...
Page 12: ...xii ID 04 Imager User s Manual Statement of RoHS Compliance ...
Page 26: ...1 14 ID 04 Imager User s Manual Make Menu Changes and Save in di soric ID ...
Page 44: ...2 18 ID 04 Imager User s Manual Using EZ Trax ...
Page 76: ...3 32 ID 04 Imager User s Manual Postamble ...
Page 94: ...4 18 ID 04 Imager User s Manual Additional Notes about Calibration ...
Page 154: ...6 34 ID 04 Imager User s Manual Background Color ...
Page 210: ...7 56 ID 04 Imager User s Manual Configuring EZ Trax Output ...
Page 225: ...ID 04 Imager User s Manual 8 15 Symbol Quality Options 0 Disabled 1 Enabled ...
Page 230: ...8 20 ID 04 Imager User s Manual di soric Symbol Quality Output by di soric ID ...
Page 242: ...9 12 ID 04 Imager User s Manual ...
Page 274: ...10 32 ID 04 Imager User s Manual Skew Correction ...
Page 292: ...11 18 ID 04 Imager User s Manual Request All Configuration Database Settings ...
Page 334: ...14 14 ID 04 Imager User s Manual Ordered Output Filter ...
Page 368: ...A 34 ID 04 Imager User s Manual Glossary of Terms ...