ID-04 Imager User’s Manual
A-7
Appendices
Codabar
<
K471,
status,start/stop match,start/stop output,large intercharacter
gap,fixed symbol length status,symbol length,check digit
type,check digit output
>
Interleaved 2 of 5
<
K472,
status,check digit status,check digit output status,symbol
length #1, symbol length #2, guard bar status,range mode status
>
UPC/EAN
<
K473,
UPC status,EAN status,supplemental status,separator status,
separator character,supplemental type,format UPC-E as UPC-A
>
Code 128/EAN 128
<
K474,
status,fixed symbol length status,fixed symbol
length,EAN 128 status,output format,application record separator
status,application record separator character,application record
brackets,application record padding
>
Code 93
<
K475,
status,fixed symbol length status,symbol length
>
PDF417
<
K476,
status,[unused],fixed symbol length status,fixed symbol
length,[unused],codeword collection
>
Data Matrix
<
K479,
ECC 200 status, ECC 000 status,ECC 050 status, ECC
080 status,ECC 100 status,ECC 140 status,ECC 120 status,ECC
130 status
>
QR Code
<
K480,
status
>
BC412
<
K481,
status,check digit output,fixed symbol length status,fixed
symbol length
>
DataBar-14
<
K482,
status
>
DataBar Limited
<
K483,
status
>
DataBar Expanded
<
K484,
status,fixed symbol length status,fixed symbol length
>
MicroPDF417
<
K485,
status,[unused],fixed symbol length status,fixed symbol
length
>
I/O Parameters
Power On/Reset Counts
<
K406,
power-on,resets,power-on saves,power-on flash saves
>
Time Since Reset
<
K407,
hours,minutes
>
Service Message
<
K409,
status,service message,threshold,resolution
>
Serial Verification
<
K701,
serial command echo status,serial command beep status,
control/hex output
>
Beeper
<
K702,
status
>
Quality Output
<
K704,
decodes/trigger separator,decodes/trigger status
>
Symbol Data Output
<
K705,
symbol data output status,when to output
>
Read Duration Output
<
K706,
status,separator
>
No Read Message
<
K714,
status,message
>
Bad Symbol Message
<
K715,
[unused],message
>
No Symbol Message
<
K716,
[unused],message
>
1D/Stacked Symbology Qualification
<
K717,
minimum number of bars,minimum number of qualified
scan lines,start/stop status
>
2D Symbology Qualification
<
K718,
finder pattern status,symbol size status,symbol size
1,symbol size 2,symbol size tolerance,dimension status,dimension
1,dimension 2,dimension tolerance,orientation status,orientation
value
>
Frame Information
<
K734,
output frame number,output coordinates
>
LED Configuration
<
K737,
LED mode,ISO/IEC 16022 grade
>
Image Output
<
K739,
image output mode,communication port,file format,jpeg
quality
>
Summary of Contents for ID-04
Page 1: ...ID 04 Imager User s Manual ID 04 User s Manual ...
Page 12: ...xii ID 04 Imager User s Manual Statement of RoHS Compliance ...
Page 26: ...1 14 ID 04 Imager User s Manual Make Menu Changes and Save in di soric ID ...
Page 44: ...2 18 ID 04 Imager User s Manual Using EZ Trax ...
Page 76: ...3 32 ID 04 Imager User s Manual Postamble ...
Page 94: ...4 18 ID 04 Imager User s Manual Additional Notes about Calibration ...
Page 154: ...6 34 ID 04 Imager User s Manual Background Color ...
Page 210: ...7 56 ID 04 Imager User s Manual Configuring EZ Trax Output ...
Page 225: ...ID 04 Imager User s Manual 8 15 Symbol Quality Options 0 Disabled 1 Enabled ...
Page 230: ...8 20 ID 04 Imager User s Manual di soric Symbol Quality Output by di soric ID ...
Page 242: ...9 12 ID 04 Imager User s Manual ...
Page 274: ...10 32 ID 04 Imager User s Manual Skew Correction ...
Page 292: ...11 18 ID 04 Imager User s Manual Request All Configuration Database Settings ...
Page 334: ...14 14 ID 04 Imager User s Manual Ordered Output Filter ...
Page 368: ...A 34 ID 04 Imager User s Manual Glossary of Terms ...