![Develcon Electronics DI-1135 Reference Manual Download Page 26](http://html.mh-extra.com/html/develcon-electronics/di-1135/di-1135_reference-manual_2488638026.webp)
ISDN Connection Management
Orbitor 3000 Reference Manual— 2-3
Address Connect
An Address Connect connection is an ISDN connection that is established to a specific destination Orbitor
dependent upon the destination network address contained within traffic received from the local LAN.
When a device on the local LAN wishes to establish a session with a device on a remote LAN, the local
device will send a frame with a destination address of the remote device. The Orbitor will receive the frame
and examine the destination network address contained within the frame.
If the Orbitor can determine the route to the destination network address, the frame is passed along to one of
the currently connected partner Orbitor Routers. If the destination network is not located on a currently
connected partner Orbitor, the local Orbitor will then look in the Address Connect table to determine which
partner Orbitor to call.
The Address Connect tables are used by the Orbitor to determine which remote Orbitor is called when a
specific destination network address is requested from a device on the local LAN. The Address Connect
tables are configured by the Orbitor operator.
Figure 2—2 Address Connect WAN Topology
Manual Call
A manual call is simply an operator initiated ISDN call to a remote partner Orbitor. The ISDN number is
entered by the operator and a call is made.