PASSWORDS TO ACCESS TO SUBMENUS
CONFIGURATION OF ACCESS PASSWORDS:
●
Modification of the Password
There are four password levels to be used by authorized staff.
Every level allows the access to a detemined functions depending on the staff qualification .
- The password for level 1 allows the access to the parameters assigned by programming to this
level to be protected.
The level 1 allows the access for the personnel in charge of the process,
- The password of level 2 allows the access to the
PID submenu
and to the password of level
1.
This level 2 is for the Dept. Manager or for the responsible of the process,
- The password of level 3 allows the access to the
Configuration submenu
and to the passwords
of levels 1 and 2.
This level 3 is for the application engineer to develop and program the function to fit the
process requirements.
- The password of level 4 allows the access to the
Calibration submenu
and to the passwords
of levels 1, 2 and 3.
This level 4 is for maintenance and calibration dept. in order to fulfil with quality
procedures of the involved in the control of the process.
The passwords are formed of four digits and can be set to any value between 0000 and FFFF in
hexadecimal format (the hexidecimal format includes the letters A, b, C, d, E and F, as possible
digits).
To modify the Passwords to access to the configured parameters to be shown on the submenus,
proceed as follows:
●
Modification of Password of level 1 access to parameters protected in this level.
By default, the password is set to
[0001].
To modify:
- In
[Disc] [Conf]
parameter
[P 04]
introduce the new password in
[nnnn]
.
●
Modification of Password of level 2 access to PID submenu
By default, the password is set to
[0001].
To modify:
- In
[Disc] [Conf]
parameter
[P 05]
introduce the new password in
[nnnn]
.
●
Modification of Password of level 3 access to Configuration submenu
By default, the password is set to
[0001].
To modify:
- In
[Disc] [Conf]
parameter
[P 06]
introduce the new password in
[nnnn]
.
●
Modification of Password of level 4 access to Calibration submenu
By default, the password is set to
[0001].
To modify:
- In
[Disc] [Conf]
parameter
[P 07]
introduce the new password in
[nnnn]
.
VERY IMPORTANT:
It is recommended to use easy to remember personal passwords, since if lost
or forgotten will deny the access to the submenu and force you to contact factory in order to recover
the accessibilty using the passwords set in origin.