XL™ SERIES
XL-BASIC Programming Guide 23-15
KEY
VALUE
KEY
VALUE
Right
1.0
Up
10.0
Enter
2.0
Left
20.0
Down
4.0
Cancel
40.0
Dot
8.0
On / Off
80.0
Example:
dispopen
dispclear
display “If Raining Press ENT“
x = inkey
if x=2.0 then goto 100
dispoff
end
100
digits(0)
openfile “B:\SERVICE.LOG”
writefile “Date “;date,
writefile “ Time ”;time,
writefile “ Currently raining”
closefile
dispoff
end
LEDON
Turn on the Error LED. Note the led will not turn on if the display is not turned on.
LEDOFF
Turn off the Error LED.