XL™ Series
Miscellaneous system Setup 5-3
PC Interface View Built In Display Screen
I - Site ID: Site_ID
Site ID [Site_ID ]
This option allows the user to enter in an eight character label that defines the site. This will also
be used as the filename for data files and other files related to this site. A file extension will be
added automatically when the file is created. Data files will have a numerical extension such as
.000 .001 or .002 and so on up to .099. Configuration files will have a .CFG extension. A
system log file will have a .LOG extension. Other file types will also exist using this variable as
the file name.
Note:
Since the ‘Site ID’ variable is used as a file name, it must not contain any imbedded
blanks or wildcard characters (*) and must be left justified, in other words it must be a DOS
compatible filename. Valid site ID labels may include letter, numbers, or the underscore. Spaces
are not valid characters for the site ID as they will cause an error and may prevent a file from
being opened.
PC Interface View Built In Display Screen
U - Update Firmware?
Update Firmware
This option is used to update the operating system firmware. As new versions of software are
produced, they will be placed on the web at
www.waterlog.com
. Users can download new or
even older versions of the software. The file will be a ZIP file that normally will contain two
files, first is a bin file that is the new firmware, and the second is a PDF or text file that will have
documentation on it related to the changes in the firmware. The user should read the PDF file to
make sure they understand the changes in the newer version of firmware. There may be no
reason to update a unit if the new changes are not needed. It is not necessary to update every
time a new version is released, however it is best not to let too many versions go by without
updating. Each release may also fix small problems in the code that may or may not be listed in
the update documentation. Also it is easier for the customer service group to help out on the
newer versions of firmware. Here is a step by step list of the update process.
1 - The user downloads a zip file from the web page.
2 - Unzip the files and read the update overview file to see if the new options are needed or
not.
3 - Load the bin file onto an ATA data card and insert the card into the XL.
Note: Do not put the zip file on the data card.
4 - Start the update process using the “Update Firmware” option as shown above.
Summary of Contents for H-350XL
Page 1: ...XL Series Models H 350XL H 500XL H 510XL H 522 H 522 Plus Owner s Manual ...
Page 30: ...2 16 Hardware Options and Installation XL Series ...
Page 42: ...3 12 Using The Built In Keypad Display XL Series ...
Page 46: ...4 4 PC Menu Interface Operation XL Series ...
Page 58: ...5 12 Miscellaneous System Setup XL Series ...
Page 66: ...6 8 Serial Port Options XL Series ...
Page 74: ...7 8 System Configuration Files XL Series ...
Page 84: ...8 10 System Status Menus Options XL Series ...
Page 88: ...9 4 Scanning Options XL Series ...
Page 156: ...15 12 Logging Options XL Series ...
Page 198: ...16 42 Operation with the GOES Radio XL Series ...
Page 216: ...19 6 Alarm Call Out XL Series ...
Page 234: ...21 8 Operation with the H 355 Smart Gas System XL Series ...
Page 246: ...22 12 Functions XL Series ...