22-6 Functions
XL™ Series
(ana1
>
2.5)|(ana2
>
3.5) returns 1.0
if
analog channel 1 is greater
than 2.5
OR
if
analog channel 2 is greater than 3.5,
else
it returns
0.0
Lowest Level Of Priority:
Assignments:
Fnt01 = 12.34
Assign the value of 12.34 to function 01
System Variables:
All system source variables can be used with the math functions. For example an analog input
channel can be used in a function such as Fnt01=10*ana1+32. The following is a complete list of
all the system source variables.
date
This is the current date in a YYMMDD format
time
This is the current time in a HHMMSS format
seconds
This is the current seconds, 0 to 59
minutes
This is the current minutes, 0 to 59
hours
This is the current hours, 0 to 23
day
This is the current day, 1 to 31
month
This is the current month, 1 to 12
year
This is the current year, 00 to 99, 2000 to 2099
stage
This is the last measured stage value and is adjusted using
the slope and offset. Using this variable in a function will
not cause a new measurement.
psi
This is the last measured psi value. Using this variable in a
function will not cause a new measurement.
pttemp
This is the last measured temperature value of the internal
temperature sensor in degrees C or F as configured by the user.
Using this variable in a function will not cause a new
measurement.
batt
This will cause the system to take a new battery measurement,
convert it to volts, and return the results.
Summary of Contents for H-350XL
Page 1: ...XL Series Models H 350XL H 500XL H 510XL H 522 H 522 Plus Owner s Manual ...
Page 30: ...2 16 Hardware Options and Installation XL Series ...
Page 42: ...3 12 Using The Built In Keypad Display XL Series ...
Page 46: ...4 4 PC Menu Interface Operation XL Series ...
Page 58: ...5 12 Miscellaneous System Setup XL Series ...
Page 66: ...6 8 Serial Port Options XL Series ...
Page 74: ...7 8 System Configuration Files XL Series ...
Page 84: ...8 10 System Status Menus Options XL Series ...
Page 88: ...9 4 Scanning Options XL Series ...
Page 156: ...15 12 Logging Options XL Series ...
Page 198: ...16 42 Operation with the GOES Radio XL Series ...
Page 216: ...19 6 Alarm Call Out XL Series ...
Page 234: ...21 8 Operation with the H 355 Smart Gas System XL Series ...
Page 246: ...22 12 Functions XL Series ...