background image

Start Up Guide

Portable Multi Logger

ZR-RX40

Cat. No. Z259-E1-03

Summary of Contents for ZR-RX40

Page 1: ...Start Up Guide Portable Multi Logger ZR RX40 Cat No Z259 E1 03...

Page 2: ...Up Guide Same contents as the above referenced Start Up Guide packaged in the product User s Manual Information for safe and correct use Before use connection and wiring in details language change of...

Page 3: ...1 1 2 3 Start Up Guide APPLICATION CONSIDERATIONS Please Read BEFORE USE BASIC OPERATIONS SPECIFICATIONS Portable Multi Logger ZR RX40...

Page 4: ...RODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION ABUSE MISUSE OR INAPPROPRIATE MODIFICATION OR REPAIR S...

Page 5: ...other reasons It is our practice to change model numbers when published ratings or features are changed or when significant construction changes are made However some specifications of the product ma...

Page 6: ...use of this product is in an industrial environment only Traceability Information zRepresentative in EU Omron Europe B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands zManufacturer Omron Corporati...

Page 7: ...may be significant property damage Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury or in property damage Meanings of Alert Symbols Indicates the...

Page 8: ...occur in rare occasions due to ignition rupture or combustion of the lithium battery contained in this product Never disassemble deform under pressure heat or incinerate this product Injuries from el...

Page 9: ...ck the polarity of the signals when connecting the signal cables When using the battery pack be sure to read the cautions on the battery pack carefully for correct usage Be sure to use only the specif...

Page 10: ...ays turn off the power supply when attaching or removing peripheral devices Attaching or removing of peripheral devices with the power supply on can cause malfunction or data corruption 3 Installation...

Page 11: ...Up Guide This manual 1 Utility disk Specal PC software Wave Inspire RX tryout Basic PC software Smart Viewer RX40 Start Up Guide PDF files User s Manual PDF files Wave Inspire RX Software Manual PDF...

Page 12: ...windows dialog boxes and other GUI elements displayed on the PC are indicated enclosed by brackets Visual Aids Indicates points that are important to achieve the full product performance such as opera...

Page 13: ...ons to Observe When Performing Measurement 21 Unused channels 21 Noise countermeasures 21 Setting the Date and Time 22 Descriptions of the Control Panel Keys 23 Descriptions of the Menu Screens 26 2 B...

Page 14: ...BEFORE USE Part Names 14 Connection Procedures 15 Precautions to Observe When Performing Measurement 22 Setting the Date and Time 22 Descriptions of the Control Panel Keys 23 Descriptions of the Menu...

Page 15: ...eys Analog signal input terminals LAN interface terminal USB interface terminal USB memory terminal Power jack for the humidity sensor Operation status LED POWER START CHARGE Battery cover GND termina...

Page 16: ...e Grounding Cable Use a flathead screwdriver to push the button above the ground terminal while connecting the grounding cable to the ZR RX40 Connect the other end of the cable to ground Connect the G...

Page 17: ...be within 2 GB USB memory device with security functions such as fingerprint authentication cannot be used CH1 CH20 b b Direct voltage Direct voltage input Thermocouple input Direct current input Resi...

Page 18: ...cting to a PC Use the USB LAN Interface to connect the ZR RX40 to a PC Connection Using a USB Cable Use the USB to connect the ZR RX40 to a PC If the USB cable is used install the USB driver in your P...

Page 19: ...Connection Use a LAN cable to connect the ZR RX40 to a PC Cable Types Use a crossing cable when connecting directly to a PC without using a hub Use a straight cable when using a hub LAN cable LAN cabl...

Page 20: ...ake sure the ZR RX40 s power is OFF when removing or mounting terminal units To Remove Pull the terminal unit out towards the direction indicated by the arrow while pressing the two locks at the botto...

Page 21: ...top of the terminal unit into the slots of the ZR RX40 and push in the unit until the lock tabs at the bottom of the unit are securely locked 1 Insert tabs at the top of the terminal unit into the slo...

Page 22: ...luctuate due to extraneous noise conduct the following countermeasures Results may differ according to noise type Connect the ZR RX40 s GND to ground Connect ZR RX40 s GND to measurement object s GND...

Page 23: ...ZR RX40 to a mains power outlet turn on the power switch and then leave the ZR RX40 connected for at least 24 hours How to Set the Date and Time Press the MENU key display the OTHR screen and then se...

Page 24: ...ct the channel and the and keys to change the setting values TIME DIV key Press the TIME DIV key to change the time axis display range on the waveform screen 4172 52 0 64 215 6 10 6 8 37 6 07 1 75 4 8...

Page 25: ...tatus of the key lock lamp on the monitor START STOP USB DRIVE key Press the START STOP key to perform a data capture start operation while the ZR RX40 is in the Free Running status and a data capture...

Page 26: ...ernal memory and to a USB memory device NAVI key Press the NAVI key to display operational descriptions during the Free Running status and during data capture and data replay operations 11 Digital Cal...

Page 27: ...display area Displays the input values for each channel The and keys can be used to select the active channel enlarged display Moreover the selected active channel is displayed at the very top of the...

Page 28: ...the lower limit of the scale of the currently active channel 15 Waveform display area The input signal waveforms are displayed here 16 Scale upper limit Displays the upper limit of the scale of the c...

Page 29: ...ONS Measurement Procedure 30 1 Preparations Preparations for Data Capture 31 2 Setup Setting the Temperature Measurement 32 3 Data Capture Measuring the Temperature 36 4 Data Replay Replaying Captured...

Page 30: ...form temperature measurement Purpose of data capture To measure the temperature of the target objects Measurement points 2 locations Sampling interval 1 second Data save destination USB memory device...

Page 31: ...apture 1 Connect the thermocouple to measurement object 1 and the CH 1 terminal 2 Connect the thermocouple to measurement object 2 and the CH 2 terminal 3 Connect the AC adapter 4 Insert the USB memor...

Page 32: ...keys used on the menu screens are the keys the ENTER key and the QUIT key The current cursor position is displayed in blue Use the keys to move the cursor If you press the ENTER key at the cursor posi...

Page 33: ...Destination file name Here we will create a folder named TEST in the USB memory device and then make the settings required to enable data to be captured to the TEST folder a Move the cursor to the Fi...

Page 34: ...hen press the ENTER key i Check that TEST appears opposite Folder move the cursor to the OK button and then press the ENTER key 4172 52 0 64 215 6 10 6 8 37 6 07 75 4 8 4 0 8 74514 52 4 8 9 56 46 5612...

Page 35: ...RX40 Start Up Guide 2 BASIC OPERATIONS 35 j In the screen displayed below we can check the capture destination the amount of data that can be captured and the allowable data capture time This complet...

Page 36: ...an be compared with the current input waveform in a 2 screen format a Press the REVIEW key to display the data in a 2 screen format b Move the cursor to check the captured waveforms date time and so f...

Page 37: ...nd the data capture oper ation a Press the START STOP key b A confirmation message is displayed Press the ENTER key c Data capture ends and the ZR RX40 goes into the Free Running status This completes...

Page 38: ...u want to replay has the file name that was appended automatically when the data was captured move the cursor to the OK button and then press the ENTER key c The Replay screen opens d Move the cursor...

Page 39: ...n and Trace Functions These functions enable you to make adjustments in order to view individual channels more easily and to delete waveforms that you do not need to view For example You can use trigg...

Page 40: ...3 SPECIFICATIONS SPECIFICATIONS Standard Specifications 42 External Dimensions 45...

Page 41: ...stance temperature detector Pt100 JPt100 Pt1000 IEC751 Humidity 1 0 to 100 Voltage 0 to 1 V scaling conversion Measurement accuracy 2 3 Voltage 0 1 of F S Thermocouple Type Measurement Temperature Ran...

Page 42: ...e Between input terminal GND At least 50 M at 500 VDC External Input Output Sections Logic input Pulse input Number of channels 4 4 ch Pulse input modes Revolutions mode Spans 50 500 5000 50 k 500 k 5...

Page 43: ...Web server function Operation of ZR RX40 Displays ZR RX40 s screen image on browser FTP function Transfers and deletes measured data from internal memory via network USB functions USB drive mode Trans...

Page 44: ...3 SPECIFICATIONS External Dimensions ZR RX40 Start Up Guide 45 External Dimensions 32 185 120 48 2 232 23 5 60 ZR RX40 mounting screw holes Two M4 depth 6 Unit mm...

Page 45: ...log number at the bottom of the front and back covers of this manual Revision code Date Revised contents 01 April 2007 Original production 02 August 2007 Rear view added in External Dimensions and min...

Page 46: ...Fax 81 75 344 7107 Regional Headquarters OMRON EUROPE B V Sensor Business Unit Carl Benz Str 4 D 71154 Nufringen Germany Tel 49 7032 811 0 Fax 49 7032 811 199 OMRON ELECTRONICS LLC One Commerce Drive...