Figure 64:
Tool status – Page 2
Any warnings and errors are displayed on the left.
The maximum acceleration to which the MINIMAT–EC-Servo screwdriver was exposed is
displayed on the right.
Press the key
or
, to reach the next tool status page. Type on the button
, to
update the data.
9.2.7.2 Tool
test
In the menu Tool test the angle measurement of the connected MINIMAT–EC-Servo
screwdriver can be checked.
Figure 65:
Tooltest
Press the button
, to start the angle test. Turn the drive of the
MINIMAT–EC-Servo screwdriver. The real value of the current measurement system and
the real value of the motor measurement will be displayed. To end the task press stop.
9.2.7.3 I/O
interface
All the inputs and outputs as well as the voltages at the interfaces SPS1 (GX2) and SPS2
(GX3) for the AST40 sequence controller are tested in the I/O Interface menu. The
complete interface description can be found in section
.