![Deprag AST40-1 Operating Instruction Booklet Download Page 14](http://html1.mh-extra.com/html/deprag/ast40-1/ast40-1_operating-instruction-booklet_2485170014.webp)
14
6.2 Interface
description
6.2.1 MINIMAT–EC-Servo
Screwdriver
Designation:
GX1
Plug connector:
Hybrid circular connector
6.2.2 Power
Supply
Designation:
GX8
Plug connector:
Hirschmann STASEI 200
6.2.3 Ethernet
Designation:
GX7
Plug connector:
Female connector RJ45 BULGIN PX0833
6.2.4 USB
Designation:
GX6
Plug connector:
Female connector BULGIN PX0844/A/0M50/A
6.2.5 Emergency
Stop
Designation:
GX9
Plug connector:
Binder plug connector, 4 pin, round and straight
Pin
Designation
1 STO1
2 STO2
3 GND
4 24V
Table 2:
Configuration Interface Emergency stop
IMPORTANT
The integrated I/O module of the AST40 must be fed with 24V DC to use
the emergency stop circuit.
This is done by feeding 24V DC via pins 3 and 4 at plug connector GX9
(emergency stop).
6.2.6 Printer
(optional)
Designation:
GX5
Plug connector:
SUB-D 9-pole (bushing)
Pin Designation
1 --
2 TXD
3 RXD
4 --
5 GND
6 --
7 --
8 --
9 --
Table 3:
Configuration Interface Printer
Interface setting:
9600 Baud - 8 data bits - 1 stop bit - No parity bit - No hardware flow control