![Denso GT20Q-SB User Manual Download Page 78](http://html1.mh-extra.com/html/denso/gt20q-sb/gt20q-sb_user-manual_2483241078.webp)
65
With UPC-E Add-on
- Scanned data
With 2-digit add-on:
0 X
1
X
2
X
3
X
4
X
5
X
6
C/D X
7
X
8
With 5-digit add-on:
0 X
1
X
2
X
3
X
4
X
5
X
6
C/D X
7
X
8
X
9
X
10
X
11
0:
Padding character for adjustment of the data length
X
7-11
:
Add-on code data
- Conversion to 16 digits (the application identifier “01” and PI are added at the start of the code before transmission)
With 2-digit add-on:
X
6
=0-2 0 1 PI 0 S X
1
X
2
X
6
0 0 0 0 X
3
X
4
X
5
C/D X
7
X
8
(
*
1
)
X
6
=3 0 1 PI 0 S X
1
X
2
X
3
0 0 0 0 0 X
4
X
5
C/D X
7
X
8
(
*
1
)
X
6
=4 0 1 PI 0 S X
1
X
2
X
3
X
4
0 0 0 0 0 X
5
C/D X
7
X
8
(
*
1
)
X
6
=5-9 0 1 PI 0 S X
1
X
2
X
3
X
4
X
5
0 0 0 0 X
6
C/D X
7
X
8
(
*
1
)
With 5-digit add-on:
X
6
=0-2 0 1 PI 0 S X
1
X
2
X
6
0 0 0 0 X
3
X
4
X
5
C/D X
7
X
8
X
9
X
10
X
11
(
*
1
)
X
6
=3 0 1 PI 0 S X
1
X
2
X
3
0 0 0 0 0 X
4
X
5
C/D X
7
X
8
X
9
X
10
X
11
(
*
1
)
X
6
=4 0 1 PI 0 S X
1
X
2
X
3
X
4
0 0 0 0 0 X
5
C/D X
7
X
8
X
9
X
10
X
11
(
*
1
)
X
6
=5-9 0 1 PI 0 S X
1
X
2
X
3
X
4
X
5
0 0 0 0 X
6
C/D X
7
X
8
X
9
X
10
X
11
(
*
1
)
(*1) The check digit is recalculated and transmitted, regardless of whether or not transmission is enabled.
- Conversion to 14 digits (PI is added at the start of the code before transmission)
With 2-digit add-on:
X
6
=0-2 PI 0 S X
1
X
2
X
6
0 0 0 0 X
3
X
4
X
5
C/D X
7
X
8
(
*
2
)
X
6
=3 PI 0 S X
1
X
2
X
3
0 0 0 0 0 X
4
X
5
C/D X
7
X
8
(
*
2
)
X
6
=4 PI 0 S X
1
X
2
X
3
X
4
0 0 0 0 0 X
5
C/D X
7
X
8
(
*
2
)
X
6
=5-9 PI 0 S X
1
X
2
X
3
X
4
X
5
0 0 0 0 X
6
C/D X
7
X
8
(
*
2
)
With 5-digit add-on:
X
6
=0-2 PI 0 S X
1
X
2
X
6
0 0 0 0 X
3
X
4
X
5
C/D X
7
X
8
X
9
X
10
X
11
(
*
2
)
X
6
=3 PI 0 S X
1
X
2
X
3
0 0 0 0 0 X
4
X
5
C/D X
7
X
8
X
9
X
10
X
11
(
*
2
)
X
6
=4 PI 0 S X
1
X
2
X
3
X
4
0 0 0 0 0 X
5
C/D X
7
X
8
X
9
X
10
X
11
(
*
2
)
X
6
=5-9 PI 0 S X
1
X
2
X
3
X
4
X
5
0 0 0 0 X
6
C/D X
7
X
8
X
9
X
10
X
11
(
*
2
)
(*2) The check digit is recalculated and transmitted, regardless of whether or not transmission is enabled.
EAN-13
- Scanned data
P
1
P
2
P
3
X
1
X
2
X
3
X
4
X
5
X
6
X
7
X
8
X
9
C/D
P
n
: Prefix character
- Conversion to 16 digits (the application identifier “01” and PI are added at the start of the code before transmission)
0 1 PI P
1
P
2
P
3
X
1
X
2
X
3
X
4
X
5
X
6
X
7
X
8
X
9
C/D
(
*
1
)
(*1) The check digit is recalculated and transmitted, regardless of whether or not transmission is enabled.
- Conversion to 14 digits (PI is added at the start of the code before transmission)
PI P
1
P
2
P
3
X
1
X
2
X
3
X
4
X
5
X
6
X
7
X
8
X
9
C/D
(
*
2
)
(*2) The check digit is recalculated and transmitted, regardless of whether or not transmission is enabled.