![Denso GT20Q-SB User Manual Download Page 34](http://html1.mh-extra.com/html/denso/gt20q-sb/gt20q-sb_user-manual_2483241034.webp)
21
7.1.3 Verification Result Output
(1) Verification Result Based Data Output
One of the following three data output patterns can be selected in the configuration software (ScannerSetting_2D) for each of
the two possible results, “verification matched” and “verification mismatched”.
No output will occur if “Transfer disabled” is selected.
Verification matched
Verification mismatched
1
Transfer disabled
Transfer disabled
2
Code data transfer enabled
Code data transfer enabled
3
OK transfer enabled
NG transfer enabled
(2) Confirmation via Beeper, Indicator LED, Vibrator
A match or mismatch verification result can be confirmed with the buzzer, indicator LED and vibrator.
The table below indicates the scanner operation when the beeper, indicator LED and vibrator are enabled.
Beeper
Indicator
LED
Vibrator
Vibration
enabled for
OK result
Vibration
enabled for
NG result
Verification
matched
Short beep
Blue light
Vibration
×
Verification
mismatched
Long beep
Red light
×
Vibration
(3) Scan Lock Release
The scan lock is a function used to lock the scanner in the Ready state if a mismatch occurs. Select using the configuration
software (ScannerSetting_2D).
Once the scanner enters this state, the scanner stays in the Ready state regardless of trigger switch control, and ignores any
subsequent trigger switch pulls and commands to enable Active state (R, READON, LON).
To release the scan lock, press the magic key or turn off the scanner.
Output of Registered Master Data
Read the code below to output both the master data verification part registered through the data verification reading
procedures and the code mark.
“
Master Data Output
”
code