20
7.1.2 Designating Targets for Data Verification
When designating a data verification target, “data string” or “data block” can be selected. “Data string” refers to a data area
specified by the verification start position and the number of verification digits. “Data block” refers to a CSV formatted data
block separated by commas.
(1) Data String Verification
The scanner compares data specified by the verification start position and the number of verification digits with the master
data registered in the scanner, and then outputs the result.
The verification start position can be set from 1 to 999, and the number of verification digits can be set from 1 to 99*.
(*The scanning digit numbers for Code 39, Codabar (NW-7) must be set and include the start-stop code.)
A mismatch occurs in the following instances:
1) The data in the specified area does not match the master data.
2) The code types do not match the master data (refer to the notes below).
3) There is missing data or no data in the specified area.
Example:
Master
data
Verification
start position
Number of
verification
digits
Scanned data
(for
verification)
Verification
result
345
3
3
00
345
Match
345
3
3
00
345
678
Match
345
3
3
00
34
6
Mismatch
345
3
3
00
34
Mismatch
(2) Data Block Verification
The scanner compares the CSV formatted data block separated by commas with the registered master data, and then outputs
the result.
The verification data block position can be set from 1 to 99.
A mismatch occurs in the following instances:
1) The data in the specified block does not match the master data.
2) The code types do not match the master data (refer to the notes below).
3) There is missing data or no data in the specified block.
4) The number of digits in the block for verification exceeds 99.
Example:
Master data
Verification data
block position
Scanned data (for
verification)
Verification result
345
3
0,12,
345
,6789
Match
345
3
0,12,
34
6,6789
Mismatch
345
3
0,12,
345
6,6789
Mismatch
345
3
0,12,
34
,6789
Mismatch
345
3
0,12
Mismatch
Note
: Only Type 1 code type verification judgment is carried out regardless of the code mark type setting in the
configuration software (ScannerSetting_2D). (Refer to